Welcome: HongNuo (Shenyang) General Machinery Co, LTD
Chinese   English 

Turbine Flow Meter with Temperature & OLED

Compact inline turbine flow meter that measures BOTH flow and media temperature in one device, giving real-time, uninterrupted monitoring of liquid flow and temperature inside the pipe. The precision turbine rotates with the liquid stream and a non-contact pickup converts rotation into a measurable signal (velocity-type measurement for clean, low-viscosity single-phase liquids). Self-luminous OLED display shows current flow or temperature and can be rotated for best readability; three panel keys set the flow alarm point and temperature alarm point directly on site. Outputs OUT1–OUT3 are user-configurable: flow alarm (PNP/NPN), temperature alarm, 4–20 mA flow or 4–20 mA temperature, plus pulse output. Body in 304 stainless steel with internal threads G1/4″–G1″ (DN4–DN25), flow range 0.04–10 m³/h, pressure rating 2.5 MPa, accuracy classes 0.5 / 1.0 / 2.0. Scaling- and corrosion-resistant hardened impeller with ruby bearings for long life; fully potted electronics for reliable performance in humid industrial areas. CE approved, functional safety per IEC 61508 / IEC 61511.

Turbine Flow Meter with Integrated Temperature & OLED Display (DN4–DN25) – Honno

Turbine Flow Meter with Integrated Temperature & OLED Display (DN4–DN25)

The HNF20-A is a compact inline turbine flow meter that measures BOTH liquid flow and media temperature in one instrument, providing uninterrupted real-time monitoring inside the pipe.

Fluid kinetic energy drives the turbine; a non-contact pickup converts rotation into a measurable signal (velocity-type measurement for clean, low-viscosity single-phase liquids). A self-luminous OLED shows the current flow or temperature and can be rotated for best readability. Three panel keys set the flow alarm point and temperature alarm point on site. OUT1–OUT3 are user-configurable as flow alarm (NPN/PNP), temperature alarm, 4–20 mA flow or 4–20 mA temperature, plus a pulse output.

Size: DN4 – DN25    Flow: 0.04 – 10 m³/h    Accuracy: 0.5 / 1.0 / 2.0 class    Temperature: 0 – 100 °C    Outputs: 4-20mA / pulse / dual alarm

Applications: petrochemical, electric power & energy, metallurgy & steel plants, papermaking, food production, water treatment, battery manufacturing, semiconductor cooling, machine tool cooling & lubrication, fine chemical, pharmaceutical fluid monitoring, liquid dosing & batching, low-flow water monitoring, process parameter acquisition.

Is HNF20-A the right choice for your application?

Select this model when all of the following conditions are met:

  • The medium is a clean, low-viscosity single-phase liquid (water, oils and similar) without heavy solids.

  • Pipe size is DN4–DN25 with G1/4" – G1" female thread connection.

  • Flow and temperature must be monitored in one instrument to save tap points and space.

  • Local OLED indication is needed, with a display that can be rotated to suit mounting orientation.

  • Two alarm contacts (flow/temperature), 4–20 mA and pulse outputs are required for PLC / control integration.

  • The site is humid or dusty and fully potted electronics are needed for long-term reliability.

Please consult us first if: the medium carries many hard solids or fibres, high-viscosity liquids need wet calibration, medium temperature exceeds 100 °C, pressure exceeds 2.5 MPa, gas or steam measurement is needed, or flange / hygienic clamp connections are required.

Why choose a turbine meter with temperature & OLED

Flow + temperature in one instrument

One meter outputs both flow and temperature, and dual alarm contacts directly deliver over-limit protection for both variables – no separate temperature sensor required.

Self-luminous OLED, rotatable display

A 128×64 self-luminous OLED clearly shows flow or temperature; three panel keys set flow and temperature alarm points on site. The display rotates for the best viewing angle in any mounting orientation.

Three configurable outputs, flexible integration

OUT1–OUT3 are user-assignable to flow alarm (NPN/PNP), temperature alarm, 4–20 mA flow or 4–20 mA temperature; a pulse output is also provided for easy PLC and data acquisition integration.

Long-life wetted parts, potted electronics

Hardened tungsten-alloy impeller resists scaling and corrosion; ruby bearings offer high hardness and wear resistance. Fully potted electronics suit humid industrial areas; 304 stainless body and parallel-mount capability save pipe space.

Technical Specifications

ModelHNF20-A Turbine Flow Meter with Temperature & OLED
PrincipleLiquid turbine (velocity type); fluid drives the turbine, non-contact pickup senses rotation
Measured mediaClean, low-viscosity single-phase liquids (water, oils and similar)
Nominal sizesDN4 – DN25 (G1/4", G3/8", G3/4", G1" female thread)
Liquid flow range0.04 – 10 m³/h (by size, see table below)
Accuracy classClass 0.5 / 1.0 / 2.0
Temperature range0 – 100 °C (customisable)
Max. process pressure2.5 MPa
Medium temperature0 … +100 °C
Ambient temperature−20 … +85 °C
Wetted / body material304 stainless steel (other materials by agreement)
Impeller & bearingTungsten-alloy impeller (scale/corrosion resistant); ruby bearing (high hardness, wear resistant)
Transmitter housingABS, fully potted electronics, display rotatable 360°
Display & operationOLED 128×64 self-luminous; three panel keys set flow/temperature alarm points
Output signalsOUT1–OUT3 user-configurable: flow alarm (NPN/PNP), temperature alarm, 4–20 mA flow, 4–20 mA temperature; plus pulse output
Power supply24 VDC
Approvals & standardsCE; functional safety per IEC 61508 for IEC 61511 safety applications

Flow range by size

SizeNormal range (m³/h)Extended range (m³/h)Connection / pressure
DN40.04 – 0.250.04 – 0.4G1/4" thread / 2.5 MPa
DN60.1 – 0.60.06 – 0.6G1/4" thread / 2.5 MPa
DN100.2 – 1.20.15 – 1.5G1/4" thread / 2.5 MPa
DN150.6 – 60.4 – 8G1/2" thread / 2.5 MPa
DN200.8 – 80.45 – 9G3/4" thread / 2.5 MPa
DN251 – 100.5 – 10G1" thread / 2.5 MPa

Installation & Commissioning

Confirm 4 items before ordering:

  1. Normal and maximum flow – to select DN4–DN25 size and accuracy class.

  2. Pipe thread (G1/4" – G1"), medium temperature and pressure.

  3. OUT1–OUT3 output configuration (alarm type, NPN/PNP, 4–20 mA flow or temperature).

  4. Whether the display version is required, accuracy class (0.5/1.0/2.0) and wetted material.

Align the flow arrow and keep short straight pipe runs upstream/downstream. Rotate the OLED to the best viewing angle. Use the three panel keys to set flow and temperature alarm points, wire OUT1–OUT3 to the required PLC signals per the wiring table, then verify the OLED reading and both alarm switching directions before automatic operation.

Outputs & System Integration

  • OUT1 / OUT2 alarm contacts (NPN/PNP): independently configurable as flow or temperature alarms for over-limit interlock, warning lights and equipment protection.

  • OUT3 4–20 mA analogue: switchable to flow 4–20 mA or temperature 4–20 mA for PLC analogue modules or recorders.

  • Pulse output: frequency signal proportional to flow for PLC high-speed counters or totalisers, for cumulative metering and batching.

  • OLED local display: self-luminous OLED shows flow or temperature in real time, eliminating a separate indicator.

For OEM equipment projects, please specify size, medium, output configuration and accuracy class with your enquiry.

Typical Applications

Semiconductor cooling & machine tool lubrication

Monitors small-flow liquid on semiconductor equipment and machine tool cooling/lubrication circuits; flow and temperature are watched together, alarming immediately to protect precision equipment.

Fine chemical & pharmaceutical fluids

Installed on clean process liquid lines in fine chemical and pharmaceutical production for small-bore high-accuracy flow and temperature acquisition.

Food production & water treatment

Used for clean liquid monitoring in food production, water treatment and battery manufacturing; 304 stainless wetted parts suit standard hygienic requirements.

Petrochemical & power energy

Serves as an in-line monitoring element for auxiliary cooling water, lubricating oil and process liquids in petrochemical, power, metallurgy & steel and papermaking industries.

Liquid dosing & low-flow monitoring

Pairs pulse output and alarm contacts for small-flow liquid batching, batch control and low-flow water monitoring on automated production lines.

Information Required for Selection

To confirm the correct HNF20-A configuration, please provide: normal and maximum flow, pipe thread (G1/4" – G1"), medium name & temperature, operating pressure, accuracy class (0.5/1.0/2.0), three-output configuration (alarm type, NPN/PNP, 4–20 mA flow or temperature), OLED display requirement, and wetted material preference. If necessary we will request additional details on mounting orientation and ambient conditions.

Frequently Asked Questions

Can it measure flow and temperature simultaneously?

Yes. The HNF20-A measures liquid flow and media temperature (0–100 °C) in one instrument, outputting both variables via OLED and dual alarm contacts.

Which thread sizes cover DN4 to DN25?

DN4/DN6/DN10 use G1/4", DN15 uses G1/2", DN20 uses G3/4" and DN25 uses G1" female thread, covering small-bore threaded piping from DN4 to DN25.

Does the OLED rotate for easier reading?

Yes. The self-luminous OLED can be rotated to the best viewing angle; three panel keys set flow and temperature alarm points on site.

How can three outputs be assigned to flow temperature alarms and analogue signals?

OUT1–OUT3 are user-configurable as flow alarm (NPN/PNP), temperature alarm, 4–20 mA flow or 4–20 mA temperature, plus a pulse output – flexible for your PLC requirements.

What clean liquid flow range is available for these small-bore turbine meters?

The overall range is 0.04–10 m³/h: DN4 0.04–0.25, DN6 0.1–0.6, DN10 0.2–1.2, DN15 0.6–6, DN20 0.8–8, DN25 1–10 m³/h, with extended ranges available.

Downloads

HNF20-A Turbine Flow Meter with Temperature & OLED Datasheet (PDF)

Insert the download link here after uploading the PDF to your website.

Need us to verify your application?

Send us pipe thread, flow range, medium temperature/pressure, output configuration and accuracy class, and we will confirm whether HNF20-A is suitable and provide a selection recommendation before quotation.

Submit your application details »

INQUIRY

CATEGORIES

CONTACT US

Contact: HongNuo

Phone: 13840589744

Tel: 86-13840589744

Email: Guiyang.bai@honno-auto. com

Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province