A flow meter inquiry often arrives as one sentence: we need a flow meter, max 20 m³/h. What follows is four emails — what is the pipe size, what is the medium, what output do you need, where does it go. Two weeks later the quote is still not settled.
The supplier is usually not the slow part. The missing items are already on the customer's site. Nobody told them which ones matter, or why.
So this article does one thing: it lays out the list that gets asked once. Six basic data points, plus three more for whichever family you are buying. Nine in total, and the reply is a complete quote — no back-and-forth.
Flow, pressure, temperature and level can sit in the same plant and still need different paperwork. Flow needs the bore and three flow figures. Pressure needs the range and the diaphragm. Temperature needs the insertion length. Level needs the tank height and whether anything is stirring it.
Different measurements — but one set of basic data underneath.
| # | Send this | Exactly what | What goes wrong without it |
|---|---|---|---|
| 1 | Pipe and connection | Pipe OD × wall, material, thread / flange / clamp size. For inline meters: pipe size first, then the connection. | The quoted unit does not fit the plant. |
| 2 | Medium | Name and concentration — "5% NaOH", not "water". Corrosive, viscous, solids, crystallising? | Wetted material and principle depend on it. |
| 3 | Temperature | Min / normal / max, three numbers in °C. | Max decides whether the model is allowed at all. |
| 4 | Pressure | Normal / max, plus vacuum or water hammer. | Under-spec it and the joint leaks in year one. |
| 5 | Output signal | 4–20 mA / relay / PNP / NPN / RS-485 / pulse, and the PLC input type. | The unit works, the panel reads nothing. |
| 6 | Power and protection | 24 V DC or 220 V AC; IP rating; hazardous area; indoor or outdoor. | No such supply on site, or not sealed enough. |
Items 1 and 5 are the two most often left out. The pipe spec decides whether it bolts on. The output decides whether the panel reads it. Get both ends right and the meter in between is worth something.
The family-specific data depends on which product you are buying.
Bore is where flow inquiries go wrong. It is sized from the minimum flow, not picked from whatever pipe is already there.
| # | Send this | Exactly what | What goes wrong without it |
|---|---|---|---|
| 7 | Flow range | Min / normal / max, one unit. | Bore follows the minimum; only the maximum means an oversized bore. |
| 8 | Fluid properties and accuracy | µS/cm for electromagnetic; solids % and cSt for ultrasonic. Typical accuracy 0.5% for inline meters, 2–3% for clamp-on. | Wrong principle — reads zero with no alarm. |
| 9 | Line conditions | Full pipe, enough straight run, can it be shut down to fit. | Installed, but no usable signal. |
Beyond the range, say whether it is gauge, absolute or vacuum. Those three are three different model codes.
| # | Send this | Exactly what | What goes wrong without it |
|---|---|---|---|
| 7 | Range, type and accuracy | Normal and max pressure; gauge, absolute or vacuum. Typically ±0.5%. | Wrong range reads nothing or bursts; the accuracy class alone moves the price a long way. |
| 8 | Wetted parts and diaphragm | Corrosive, viscous, solids, crystallising? Flush diaphragm, sanitary clamp, high purity? | Wrong diaphragm blocks or perforates within months. |
| 9 | Switch or transmitter | Switches: setpoint and reset differential. Transmitters: process and electrical connection, remote seal or capillary. | No setpoint means the switch ships at its default. |
Sensor type and insertion length are two separate things. The first decides whether the reading is right. The second decides whether you measure the fluid or the pipe wall.
| # | Send this | Exactly what | What goes wrong without it |
|---|---|---|---|
| 7 | Range, type and accuracy | Min and max temperature; tolerance; RTD or thermocouple. | Wrong type and the reading is simply wrong — often full scale or jumping. This is not an offset, calibration will not save it; you reconfigure or replace. |
| 8 | Insertion length and connection | Probe length, thread size, pipe or tank mounting. | Too short a probe measures the wall, not the fluid. |
| 9 | Sheath material and form | 316L, PFA/PTFE for corrosion, sanitary, or non-contact infrared. | Wrong material perforates within a season. |
Tank height is the starting point, not the answer. Agitation, foam and build-up usually decide the principle before the range does.
| # | Send this | Exactly what | What goes wrong without it |
|---|---|---|---|
| 7 | Range, mounting and accuracy | Tank height, high and low levels, top or side mounting. ±5 mm or ±1 mm? | Too short a range loses the high level; a 1 mm signal and a 5 mm signal are very different. |
| 8 | Process disturbance | Agitation, foam, vapour, build-up; density or dielectric constant. | Wrong principle, fluctuating or false readings. |
| 9 | Continuous or switching | Continuous: 4–20 mA / RS-485. Switching: how many points, action, hazardous area. | It arrives able to alarm but unable to measure. |
A DN25 cooling loop, 26 mm bore, minimum 0.2 m³/h, maximum 15 m³/h. The usual way this arrives by email is three words: max 15.
0.2 m³/h is 0.10 m/s and 15 m³/h is 7.8 m/s. The clamp-on is specified 0.1–5.0 m/s with an accuracy band of 0.3–5.0 m/s, so neither figure sits inside it. A different model of the same thing does not fix this — a smaller bore at the measuring point, or a different principle, does.
An inquiry that only says "max 15" finds this out after the meter is on site, installed, and reading nothing. By then it is not returnable.
Back to "max 20 m³/h". With the bore, the three flow figures and the medium in that first email, the first reply can carry a model code and a price instead of four questions.
We do not guess data. If something is missing we ask, rather than quote low now and revise after the drawing is confirmed — the week that saves gets spent twice over later.
Contact us for the one-page quote data sheet.