Sensor-plus-transmitter Coriolis meter measuring mass flow directly, unaffected by density, temperature, pressure or velocity distribution; the vibrating tube derives mass flow from frequency, phase difference and amplitude, while density and temperature are measured simultaneously. DSP+ARM transmitter with LCD, self-check and self-diagnosis, two independently configurable outputs, no obstacles or moving parts. Accuracy grades 0.1/0.15/0.2/0.5/1.0%, range ratio 100:1 (1000:1 low-frequency), DN01–DN250 to 30,000 kg/min; conventional, high-pressure, cryogenic and sanitary straight-tube series; 316L wetted parts with 904L, titanium, Hastelloy, duplex and tantalum options.
The HNF90 Coriolis mass flow meter consists of a sensor and a transmitter and measures the mass flow rate of a fluid directly, so results are not affected by density, temperature, pressure or velocity-distribution characteristics, eliminating the errors of volumetric measurement. The flow tube is vibrated and the sensor analyses changes in frequency, phase difference and amplitude to determine mass flow, while density is calculated from the vibration frequency and temperature is measured at the same time: one instrument replaces several. The transmitter uses a DSP + ARM intelligent control system with LCD display, fast parameter setting, self-check and self-diagnostic functions, and two independently configurable output signals for flow rate, density or temperature. There are no obstacles or moving parts in the pipeline, service life is long, maintenance is low, damping time is adjustable, and communication capability is strong.
The HNF90 covers nominal sizes DN01–DN250 (1/12″–10″) with maximum flow up to 30,000 kg/min. Four application series match conventional liquids and gases, high-pressure hydrogen/CNG, cryogenic LNG and chemical-energy duties, and sanitary filling. Wetted materials start from 316L with high-nickel 316L, 904L, titanium, C4 steel, Hastelloy, duplex steel and tantalum options.
Good fit: petrochemical and oil loading, natural gas/CNG/LNG, hydrogen refuelling, LPG and CO₂, chemicals and acids, lithium electrolyte, photovoltaic polysilicon, food and beverage oils, filling machines, metallurgy, paper, refrigeration, air separation, mud and steam.
Choose HNF90 when:
You need direct mass flow, density and temperature in one instrument, independent of fluid viscosity and density.
The duty covers small to large flow, liquid or gas, or requires high-pressure, cryogenic or hygienic construction.
You need 4–20 mA, HART, Modbus RTU/RS-485, pulse or Profibus PA to a PLC or DCS.
Confirm with us first for abrasive solids-laden fluids, temperatures outside the selected series, pressure ratings above the selected flow-tube grade, or special sanitary and certification requirements.
The flow tube carrying the medium is vibrated; the sensor detects and analyses changes in frequency, phase difference and amplitude to measure the mass of medium passing through, and density is derived from the vibration frequency. Mass flow, volume flow, density and temperature are measured simultaneously. The DSP + ARM transmitter processes the signals, drives the LCD, and provides two independently configurable outputs; adjustable damping time stabilises the reading, and self-check/self-diagnosis supports fault finding.
| Model | HNF90 Coriolis mass flow meter (sensor + transmitter) |
|---|---|
| Measured variables | Mass flow, volume flow, density, temperature |
| Accuracy | Grades 0.1 / 0.15 / 0.2 / 0.5 / 1.0 % of flow rate; liquid up to ±0.1 %, gas up to ±0.25 % |
| Repeatability | 0.075 / 0.1 / 0.25 / 0.5 % of flow |
| Density accuracy | ±0.001 g/cm³ (±1 kg/m³); selectable 0.003 / 0.001 / 0.0005 / 0.0002 / 0.00015 g/ml |
| Temperature accuracy | ±1 ℃ or ±0.5 % of test value; temperature repeatability 0.2 ℃ |
| Range ratio | 100:1; up to 1000:1 with low-frequency sensors |
| Nominal size | DN01–DN250 (1/12″–10″); maximum flow up to 30,000 kg/min |
| Medium temperature | Standard −40…85 ℃; high-temperature 85–200 ℃; ultra-high-temperature 200–350 ℃ (U-tube only); cryogenic down to −200 ℃ |
| Explosion protection | Ex d ib IIC T6 Gb; Zone 1 and Zone 2, compatible with IIA/IIB; certification CQEx22.0774X |
| Protection class | IP67 |
| Relative humidity | ≤95 % RH |
| Output | Modbus RTU/RS-485 + active pulse (default); 4–20 mA active; HART + 4–20 mA; Profibus PA + Modbus/pulse |
| Power supply | 24 VDC; or 220 VAC / 24 VDC adaptive |
| Electrical interface | M20×1.5 (default) or 1/2″ NPT |
| Transmitter versions | CLS100 / CLS200 / CLS300; integrated or split (3 m cable standard); display optional; insulation jacket optional |
| Series | Code | Coverage | Typical duty |
|---|---|---|---|
| Conventional | T | DN01–DN250, −40…85 ℃ | Trade handover and process control in petrochemical, metallurgy, power, paper, semiconductor |
| High-voltage | P | DN04 / DN08 / DN15; WP up to 87.5 / 45 / 25 MPa | High-pressure gas, hydrogen and CNG; hydrogen-embrittlement-resistant wetted parts |
| Cryogenic | L | DN08 / DN25 / DN40 / DN50 / DN80; −200…+85 ℃; WP ≤4 MPa | LNG, natural gas and cryogenic applications |
| Sanitary straight-tube | S | DN04–DN100, −40…85 ℃ | Filling and hygienic duty; 3-A, EHEDG tested, CIP/SIP; aluminium or stainless housing |
| Model | DN | Max flow (kg/min) | Max flow (lb/min) |
|---|---|---|---|
| HNF9001TU | DN01 | 0.58 | 1.27 |
| HNF9008TU | DN08 | 25 | 55 |
| HNF9025TU | DN25 | 220 | 485 |
| HNF9050TU | DN50 | 850 | 1874 |
| HNF9080TU | DN80 | 2900 | 6393 |
| HNF90150TU | DN150 | 12000 | 26455 |
| HNF90250TU | DN250 | 30000 | 66138 |
The full conventional-series table lists every DN from DN01 to DN250 with maximum flow in kg/min and lb/min; cryogenic and high-pressure series have their own flow and pressure ratings.
| Code segment | Options |
|---|---|
| Nominal diameter | 001 DN01 … 250 DN250 (DN01/02/03/04/08/15/20/25/32/40/50/65/80/100/150/200/250) |
| Application code | T conventional; P high-voltage; L cryogenic; S sanitary; G high-temperature 85–200 ℃; C ultra-high-temperature 200–350 ℃; X special |
| Sensor series | U U-shaped; W micro-bending; L straight tube; D inverted triangle; X special |
| Flow-tube pressure | 02 1.6 / 04 4 / 06 6 / 10 10 / 20 20 / 25 25 / 35 35 / 45 45 / 70 70 / 96 96 MPa |
| Tube material | S 316L (default); G 316L high nickel; L 904L; T titanium; C C4 steel; H Hastelloy; D duplex; A tantalum; X other |
| Accuracy class | S 0.1; A 0.15; B 0.2; C 0.5; D 1.0; X other |
| Transmitter installation | N integrated; S split (3 m cable default); J compact integrated (non-Ex); D rail mount (non-Ex); X other |
| Output | M Modbus RTU/RS-485 + active pulse; L 4–20 mA; H HART + 4–20 mA; P Profibus PA + Modbus/pulse; X other |
| Power supply | 1 24 VDC; 2 220 VAC / 24 VDC adaptive; X other |
| Electrical interface | M M20×1.5 (default); N 1/2″ NPT; X special |
| Transmitter version | V1 CLS100 (default); V2 CLS200; V3 CLS300; XX other |
| Measurement mode | M mass; D density; A mass + density; X other |
| Display | C CLS100C with display; M CLS100 without display (default); X other |
| Certification | N none; C Ex explosion-proof; A 3-A; S special equipment production license; X other |
Process connections cover HG/T20592 and HG/T20615 flanges, ASME B16.5 Class 150–2500, EN 1092-1, JIS B2220, GB/T9115, DIN 11851/11864 and SMS 1145 sanitary fittings, tri-clamp, VCO, NPT and UNF threads.
Mount the sensor according to the vibration-prone and flow-direction requirements; keep the run free from strong external vibration and avoid stress from piping alignment.
Match tube and connection materials to the medium; choose tantalum, Hastelloy, duplex or 904L for aggressive or corrosive service.
For high-pressure hydrogen/CNG, verify the flow-tube pressure grade and hydrogen-embrittlement-resistant wetted parts before ordering.
For hygienic duties, confirm the 3-A/EHEDG configuration, sanitary connection and CIP/SIP compatibility.
Oil & gas: crude/refined oil loading, LPG, natural gas, CNG/LNG, hydrogen refuelling, CO₂ and industrial gas.
Chemicals & energy: methanol, peroxide, resin, xylene, acids and alkali, caustic soda, ammonia, steam and mud, air separation, refrigeration.
New materials: lithium electrolyte, photovoltaic polysilicon (SiHCl₃ / SiCl₄), high-viscosity resin and coating.
Food & pharma: edible/palm/peanut oil, flavourants, blended oil, drinks, filling machines, pharmaceutical and fine chemicals.
Send: medium and its composition, normal and maximum flow, operating pressure and temperature, DN or pipe size, required series (conventional / high-pressure / cryogenic / sanitary), output, tube and connection material, pressure rating, certification, and integrated or split installation. We will confirm the type, materials and selection code before quoting.
Can it measure mass flow, density and temperature together?
Yes. The Coriolis sensor measures mass flow directly, density from vibration frequency, and temperature at the same time; two independently configurable outputs carry flow, density or temperature.
Which materials handle cryogenic or corrosive fluids?
Wetted options include 316L, 316L high nickel, 904L, titanium, C4 steel, Hastelloy, duplex and tantalum. The cryogenic series reaches −200 ℃; match aggressive media to the corrosion-resistant grade.
Does pressure affect direct mass flow measurement?
No. The direct mass-flow reading is not affected by medium density, temperature, pressure or velocity distribution, eliminating volumetric-measurement errors.
How does it reach a 100:1 range ratio without moving parts?
The vibrating flow tube has no moving parts in the pipeline; the DSP + ARM transmitter processes frequency, phase and amplitude. Range ratio reaches 100:1, up to 1000:1 with low-frequency sensors.
What accuracy is available for liquid and gas mass flow?
Grades 0.1 / 0.15 / 0.2 / 0.5 / 1.0 % of flow rate; liquid up to ±0.1 %, gas ±0.25 %, repeatability from 0.075 % of flow.
HNF90 Coriolis Mass Flow Meter Datasheet (PDF) — view all product manuals on our Download page »
Send the medium, flow, pressure, temperature and pipe size. We will confirm the series, materials and selection code before quotation.
Send us your application details »
Contact: HongNuo
Phone: 13840589744
Tel: 86-13840589744
Email: Guiyang.bai@honno-auto. com
Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province
We chat