Welcome: HongNuo (Shenyang) General Machinery Co, LTD
Chinese   English 

HNF90 Coriolis Mass Flow Meter for Liquids & Gases, DN1–DN250

Sensor-plus-transmitter Coriolis meter measuring mass flow directly, unaffected by density, temperature, pressure or velocity distribution; the vibrating tube derives mass flow from frequency, phase difference and amplitude, while density and temperature are measured simultaneously. DSP+ARM transmitter with LCD, self-check and self-diagnosis, two independently configurable outputs, no obstacles or moving parts. Accuracy grades 0.1/0.15/0.2/0.5/1.0%, range ratio 100:1 (1000:1 low-frequency), DN01–DN250 to 30,000 kg/min; conventional, high-pressure, cryogenic and sanitary straight-tube series; 316L wetted parts with 904L, titanium, Hastelloy, duplex and tantalum options.

HNF90 Coriolis Mass Flow Meter

The HNF90 Coriolis mass flow meter consists of a sensor and a transmitter and measures the mass flow rate of a fluid directly, so results are not affected by density, temperature, pressure or velocity-distribution characteristics, eliminating the errors of volumetric measurement. The flow tube is vibrated and the sensor analyses changes in frequency, phase difference and amplitude to determine mass flow, while density is calculated from the vibration frequency and temperature is measured at the same time: one instrument replaces several. The transmitter uses a DSP + ARM intelligent control system with LCD display, fast parameter setting, self-check and self-diagnostic functions, and two independently configurable output signals for flow rate, density or temperature. There are no obstacles or moving parts in the pipeline, service life is long, maintenance is low, damping time is adjustable, and communication capability is strong.

INQUIRY

One Meter for Mass Flow, Density and Temperature

The HNF90 covers nominal sizes DN01–DN250 (1/12″–10″) with maximum flow up to 30,000 kg/min. Four application series match conventional liquids and gases, high-pressure hydrogen/CNG, cryogenic LNG and chemical-energy duties, and sanitary filling. Wetted materials start from 316L with high-nickel 316L, 904L, titanium, C4 steel, Hastelloy, duplex steel and tantalum options.

Good fit: petrochemical and oil loading, natural gas/CNG/LNG, hydrogen refuelling, LPG and CO₂, chemicals and acids, lithium electrolyte, photovoltaic polysilicon, food and beverage oils, filling machines, metallurgy, paper, refrigeration, air separation, mud and steam.

Is HNF90 Suitable for Your Application?

Choose HNF90 when:

  • You need direct mass flow, density and temperature in one instrument, independent of fluid viscosity and density.

  • The duty covers small to large flow, liquid or gas, or requires high-pressure, cryogenic or hygienic construction.

  • You need 4–20 mA, HART, Modbus RTU/RS-485, pulse or Profibus PA to a PLC or DCS.

Confirm with us first for abrasive solids-laden fluids, temperatures outside the selected series, pressure ratings above the selected flow-tube grade, or special sanitary and certification requirements.

Working Principle

The flow tube carrying the medium is vibrated; the sensor detects and analyses changes in frequency, phase difference and amplitude to measure the mass of medium passing through, and density is derived from the vibration frequency. Mass flow, volume flow, density and temperature are measured simultaneously. The DSP + ARM transmitter processes the signals, drives the LCD, and provides two independently configurable outputs; adjustable damping time stabilises the reading, and self-check/self-diagnosis supports fault finding.

Technical Specifications

ModelHNF90 Coriolis mass flow meter (sensor + transmitter)
Measured variablesMass flow, volume flow, density, temperature
AccuracyGrades 0.1 / 0.15 / 0.2 / 0.5 / 1.0 % of flow rate; liquid up to ±0.1 %, gas up to ±0.25 %
Repeatability0.075 / 0.1 / 0.25 / 0.5 % of flow
Density accuracy±0.001 g/cm³ (±1 kg/m³); selectable 0.003 / 0.001 / 0.0005 / 0.0002 / 0.00015 g/ml
Temperature accuracy±1 ℃ or ±0.5 % of test value; temperature repeatability 0.2 ℃
Range ratio100:1; up to 1000:1 with low-frequency sensors
Nominal sizeDN01–DN250 (1/12″–10″); maximum flow up to 30,000 kg/min
Medium temperatureStandard −40…85 ℃; high-temperature 85–200 ℃; ultra-high-temperature 200–350 ℃ (U-tube only); cryogenic down to −200 ℃
Explosion protectionEx d ib IIC T6 Gb; Zone 1 and Zone 2, compatible with IIA/IIB; certification CQEx22.0774X
Protection classIP67
Relative humidity≤95 % RH
OutputModbus RTU/RS-485 + active pulse (default); 4–20 mA active; HART + 4–20 mA; Profibus PA + Modbus/pulse
Power supply24 VDC; or 220 VAC / 24 VDC adaptive
Electrical interfaceM20×1.5 (default) or 1/2″ NPT
Transmitter versionsCLS100 / CLS200 / CLS300; integrated or split (3 m cable standard); display optional; insulation jacket optional

Four Application Series

SeriesCodeCoverageTypical duty
ConventionalTDN01–DN250, −40…85 ℃Trade handover and process control in petrochemical, metallurgy, power, paper, semiconductor
High-voltagePDN04 / DN08 / DN15; WP up to 87.5 / 45 / 25 MPaHigh-pressure gas, hydrogen and CNG; hydrogen-embrittlement-resistant wetted parts
CryogenicLDN08 / DN25 / DN40 / DN50 / DN80; −200…+85 ℃; WP ≤4 MPaLNG, natural gas and cryogenic applications
Sanitary straight-tubeSDN04–DN100, −40…85 ℃Filling and hygienic duty; 3-A, EHEDG tested, CIP/SIP; aluminium or stainless housing

Representative Conventional Max Flow

ModelDNMax flow (kg/min)Max flow (lb/min)
HNF9001TUDN010.581.27
HNF9008TUDN082555
HNF9025TUDN25220485
HNF9050TUDN508501874
HNF9080TUDN8029006393
HNF90150TUDN1501200026455
HNF90250TUDN2503000066138

The full conventional-series table lists every DN from DN01 to DN250 with maximum flow in kg/min and lb/min; cryogenic and high-pressure series have their own flow and pressure ratings.

Selection Code

Code segmentOptions
Nominal diameter001 DN01 … 250 DN250 (DN01/02/03/04/08/15/20/25/32/40/50/65/80/100/150/200/250)
Application codeT conventional; P high-voltage; L cryogenic; S sanitary; G high-temperature 85–200 ℃; C ultra-high-temperature 200–350 ℃; X special
Sensor seriesU U-shaped; W micro-bending; L straight tube; D inverted triangle; X special
Flow-tube pressure02 1.6 / 04 4 / 06 6 / 10 10 / 20 20 / 25 25 / 35 35 / 45 45 / 70 70 / 96 96 MPa
Tube materialS 316L (default); G 316L high nickel; L 904L; T titanium; C C4 steel; H Hastelloy; D duplex; A tantalum; X other
Accuracy classS 0.1; A 0.15; B 0.2; C 0.5; D 1.0; X other
Transmitter installationN integrated; S split (3 m cable default); J compact integrated (non-Ex); D rail mount (non-Ex); X other
OutputM Modbus RTU/RS-485 + active pulse; L 4–20 mA; H HART + 4–20 mA; P Profibus PA + Modbus/pulse; X other
Power supply1 24 VDC; 2 220 VAC / 24 VDC adaptive; X other
Electrical interfaceM M20×1.5 (default); N 1/2″ NPT; X special
Transmitter versionV1 CLS100 (default); V2 CLS200; V3 CLS300; XX other
Measurement modeM mass; D density; A mass + density; X other
DisplayC CLS100C with display; M CLS100 without display (default); X other
CertificationN none; C Ex explosion-proof; A 3-A; S special equipment production license; X other

Process connections cover HG/T20592 and HG/T20615 flanges, ASME B16.5 Class 150–2500, EN 1092-1, JIS B2220, GB/T9115, DIN 11851/11864 and SMS 1145 sanitary fittings, tri-clamp, VCO, NPT and UNF threads.

Installation Notes

  • Mount the sensor according to the vibration-prone and flow-direction requirements; keep the run free from strong external vibration and avoid stress from piping alignment.

  • Match tube and connection materials to the medium; choose tantalum, Hastelloy, duplex or 904L for aggressive or corrosive service.

  • For high-pressure hydrogen/CNG, verify the flow-tube pressure grade and hydrogen-embrittlement-resistant wetted parts before ordering.

  • For hygienic duties, confirm the 3-A/EHEDG configuration, sanitary connection and CIP/SIP compatibility.

Typical Applications

  • Oil & gas: crude/refined oil loading, LPG, natural gas, CNG/LNG, hydrogen refuelling, CO₂ and industrial gas.

  • Chemicals & energy: methanol, peroxide, resin, xylene, acids and alkali, caustic soda, ammonia, steam and mud, air separation, refrigeration.

  • New materials: lithium electrolyte, photovoltaic polysilicon (SiHCl₃ / SiCl₄), high-viscosity resin and coating.

  • Food & pharma: edible/palm/peanut oil, flavourants, blended oil, drinks, filling machines, pharmaceutical and fine chemicals.

What to Send Us for Selection

Send: medium and its composition, normal and maximum flow, operating pressure and temperature, DN or pipe size, required series (conventional / high-pressure / cryogenic / sanitary), output, tube and connection material, pressure rating, certification, and integrated or split installation. We will confirm the type, materials and selection code before quoting.

Frequently Asked Questions

Can it measure mass flow, density and temperature together?

Yes. The Coriolis sensor measures mass flow directly, density from vibration frequency, and temperature at the same time; two independently configurable outputs carry flow, density or temperature.

Which materials handle cryogenic or corrosive fluids?

Wetted options include 316L, 316L high nickel, 904L, titanium, C4 steel, Hastelloy, duplex and tantalum. The cryogenic series reaches −200 ℃; match aggressive media to the corrosion-resistant grade.

Does pressure affect direct mass flow measurement?

No. The direct mass-flow reading is not affected by medium density, temperature, pressure or velocity distribution, eliminating volumetric-measurement errors.

How does it reach a 100:1 range ratio without moving parts?

The vibrating flow tube has no moving parts in the pipeline; the DSP + ARM transmitter processes frequency, phase and amplitude. Range ratio reaches 100:1, up to 1000:1 with low-frequency sensors.

What accuracy is available for liquid and gas mass flow?

Grades 0.1 / 0.15 / 0.2 / 0.5 / 1.0 % of flow rate; liquid up to ±0.1 %, gas ±0.25 %, repeatability from 0.075 % of flow.

Datasheet Download

HNF90 Coriolis Mass Flow Meter Datasheet (PDF) — view all product manuals on our Download page »

Need Us to Check the Application?

Send the medium, flow, pressure, temperature and pipe size. We will confirm the series, materials and selection code before quotation.

Send us your application details »


INQUIRY

CATEGORIES

CONTACT US

Contact: HongNuo

Phone: 13840589744

Tel: 86-13840589744

Email: Guiyang.bai@honno-auto. com

Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province