The HNF80-A Thermal Gas Flow Switch/Flow Meter is an instrument that utilizes the principle of heat conduction to measure flow. The meter utilizes the constant temperature difference method to accurately measure gas flow. It has the advantages of small size, high digitization, easy installation and accurate measurement. The fluid pipe is equipped with a heated NTC, once a fluid flows through, it will take away the heat of the NTC, the heat taken away by the NTC, the resistance value rises, the rate of rise and the fluid flow rate has a certain relationship, so it can be detected through the measurement of this resistance value, the flow rate. HNF80-A Thermal Gas Flow Switch/Flow Meter is an instrument that utilizes the principle of heat conduction to measure the flow rate. The meter utilizes the constant temperature difference method to accurately measure gas flow. It has
Small size, high degree of digitization, easy installation, accurate measurement and other advantages. The fluid pipe is equipped with a heated NTC, once the fluid flows through, it will take away the heat of the NTC, the heat taken away by the NTC, the resistance value rises, the rate of rise and the fluid flow rate has a certain relationship, so it can be detected by measuring the resistance value of the flow rate. In addition, a temperature sensor is built in to compensate for the fluid temperature or ambient temperature, so stable measurement is possible within the operating temperature range.
HNF80-A Thermal Micro Gas Mass Flow Meter (5–2000 L/min)
The HNF80-A thermal gas flow meter measures small gas flows using the constant-temperature-difference principle: a heated NTC element sits in the gas stream, and the heat carried away by flowing gas changes its resistance at a rate proportional to flow velocity. A built-in temperature sensor compensates for gas or ambient temperature changes. The integrated LCD shows both instantaneous and cumulative flow, with switch, pulse and analog outputs in one compact body — ideal for equipment-level and plant-level gas consumption monitoring.
The HNF80-A is an instrument that measures gas flow based on the heat-conduction principle using the constant-temperature-difference method. It offers small volume, high digitization, convenient installation and accurate measurement.
A heated NTC element is installed in the gas pipeline. Once gas flows through, it carries heat away from the NTC; the resulting resistance rise rate has a fixed relationship with flow velocity. The meter reads this resistance to determine flow. An onboard temperature sensor compensates for gas or ambient temperature drift, ensuring stable readings across the operating range.
Typical conditions: dry air, nitrogen and other clean gases; small flows from 5 to 2000 L/min; equipment integration or plant-level air consumption monitoring; when a local digital display and multiple output signals are needed.
Choose this model when the following conditions are met:
Measuring medium is dry air or nitrogen and other clean, dry gases (not suitable for gas with liquid droplets, dust or corrosive components)
Flow range falls within 5–500 L/min (501), 10–1000 L/min (102) or 20–2000 L/min (202)
Fluid temperature 0–50°C, operating pressure 0–0.8 MPa
Local LCD display is required (instantaneous flow + switchable cumulative flow)
Outputs needed: PNP/NPN switch + analog (4–20mA / 1–5V) + pulse output
Port is Rc1/2, NPT1/2, G1/2 (501/102) or Rc3/4, NPT3/4, G3/4 (202)
Please confirm with us first if: the gas contains moisture, oil mist, dust or corrosive components; temperature is outside 0–50°C; pressure exceeds 0.8 MPa; or the measured gas is not dry air/nitrogen (flow factor must be recalibrated).
The thermal principle directly reflects gas mass flow, so no additional temperature or pressure compensation is needed to obtain standard-state flow — reducing installation and conversion effort.
Ranging from 5 L/min, it covers equipment-level micro gas monitoring. The LCD main screen shows instantaneous flow; the sub-screen switches to cumulative flow, set values, peak/valley values and line names — no separate display instrument required.
A single instrument integrates switch output (PNP/NPN selectable), cumulative pulse and analog output (4–20mA or 1–5V/0–10V), connecting simultaneously to PLCs, counters and data acquisition systems.
Integral inline body requires only ≥8 cm straight pipe on the inlet side. The display rotates 90° for the best reading angle, and the M8 connector makes wiring quick — suitable for OEM equipment integration.
| Item | Specification |
|---|---|
| Model | HNF80-A-501 / HNF80-A-102 / HNF80-A-202 |
| Measuring medium | Dry air |
| Fluid temperature range | 0–50°C |
| Detection method | Thermal type (constant-temperature-difference) |
| Rated flow range | 5–500 L/min (501); 10–1000 L/min (102); 20–2000 L/min (202) |
| Instantaneous flow setting range | 5–525 / 10–1050 / 20–2100 L/min |
| Cumulative flow range | 0–999,999,999 L |
| Minimum setting unit | Instantaneous: 1 L/min; Cumulative: 1 L |
| Pulse conversion value | 1 L/pulse or 10 L/pulse (pulse width = 50 ms) |
| Rated pressure range | 0–0.8 MPa (proof pressure 1.2 MPa) |
| Pressure characteristic | ±5% F.S. (at 25°C, 0.6 MPa reference) |
| Power supply | DC 12–24V ±10% |
| Current consumption | ≤55 mA |
| Display accuracy | ±3% F.S. |
| Analog output accuracy | ±3% F.S. |
| Repeatability | ±1% F.S. (±2% F.S. when 0.05 s response is selected) |
| Temperature characteristic | ±5% F.S. (0–50°C, 25°C reference) |
| Switch output | PNP/NPN selectable, max 80 mA, NO/NC selectable, short-circuit protected |
| Analog output | Voltage: 1–5V / 0–10V (at 24V supply); Current: 4–20mA |
| Display type | LCD 3-screen: main instantaneous flow + sub cumulative/set values + unit display |
| Protection rating | IP65 |
| Withstand voltage | AC 250V / 1 min (between external terminals and housing) |
| Insulation resistance | ≥2 MΩ (DC 500V megohmmeter) |
| Operating temperature | 0–50°C |
| Storage temperature | -10–60°C (no condensation, no freezing) |
| Operating humidity | 35–85% RH (no condensation) |
| Process connections | Rc1/2, NPT1/2, G1/2 (501/102); Rc3/4, NPT3/4, G3/4 (202) |
| Wetted materials | SUS304, PPS, EPDM, Si, Au, FR4 |
| Certification | CE (EMC Directive, RoHS Directive) |
| Weight | Body 165g; cable 100g; bracket 15g |
Please confirm the following four items before ordering:
Flow range — verify normal and maximum working flow fall within the selected range (501 / 102 / 202).
Process connection — select thread type (Rc / NPT / G) and size (1/2" or 3/4").
Output type — choose switch PNP/NPN, analog 4–20mA / 1–5V / 0–10V, and pulse combination per your control system.
Mounting bracket & cable — choose with M8 connector (3m cable) or bare wires; optional mounting bracket.
Maintain ≥8 cm straight pipe on the inlet side and avoid abrupt pipe diameter changes at the inlet. The display unit rotates for the best reading angle. After installation, first confirm zero-flow reading, then compare with actual gas flow before commissioning. Wiring: Brown=DC(+), Blue=DC(-), White=OUT1, Black=OUT2/Analog.
Switch output (OUT1 / OUT2): PNP or NPN to PLC inputs or relays — configurable as hysteresis, upper/lower limit, cumulative output, cumulative pulse or abnormal alarm mode.
Analog output (OUT2): 4–20mA or 1–5V / 0–10V to PLC analog modules or data loggers for continuous flow signal transmission.
Cumulative pulse output: one pulse per 1 L or 10 L (50 ms width) to counters or PLC high-speed input channels for gas consumption totalization.
For OEM inquiries, please specify: controller input type, required flow units (L/min, G/min or cfm), pulse equivalent, and cable length requirements.
Measures high-purity process gases (nitrogen, dry air) for wire bonding, high-precision lead tension bonding and electronic component mounting equipment.
Monitors pneumatic component air consumption and department-level gas usage, helping identify leaks and optimize compressor station efficiency.
Provides stable air flow monitoring for spray booths and rail vehicle painting lines, ensuring consistent coating quality.
Used for glass furnace burner fire control, FPD handling processes and negative-ion purification gas line monitoring.
Compact, reliable gas flow feedback for food filling and packaging, leak inspection, CO₂ management, biochemical culture devices, arc-welding monitoring and machine-tool matching.
To confirm the correct HNF80-A configuration, please provide: gas type, normal and maximum flow rate, operating pressure and temperature, thread specification (Rc / NPT / G and size), required outputs (switch PNP/NPN, analog 4–20mA / 1–5V, pulse equivalent), and whether a mounting bracket or cable is needed. If the gas is not dry air or nitrogen, please specify the gas type so the flow factor can be matched accordingly.
Three models: 5–500 L/min (HNF80-A-501, 1/2" port), 10–1000 L/min (HNF80-A-102, 1/2" port) and 20–2000 L/min (HNF80-A-202, 3/4" port).
Yes. The main screen defaults to instantaneous flow; pressing the up/down key switches the sub-screen to cumulative flow, set values, peak/valley values and line names. Instantaneous and cumulative display modes can be freely toggled.
Both are available. Switch output is selectable as PNP or NPN per channel; NO/NC is selectable; maximum load current is 80 mA with short-circuit protection.
An integrated temperature sensor compensates for gas and ambient temperature fluctuations, so the thermal measurement stays stable across the 0–50°C operating range without external compensation.
The 5–500 and 10–1000 L/min models use 1/2" threads (Rc1/2, NPT1/2, G1/2). The 20–2000 L/min model uses 3/4" threads (Rc3/4, NPT3/4, G3/4).
HNF80-A Thermal Gas Mass Flow Meter Datasheet (PDF)
Contact: HongNuo
Phone: 13840589744
Tel: 86-13840589744
Email: Guiyang.bai@honno-auto. com
Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province
We chat