Welcome: HongNuo (Shenyang) General Machinery Co, LTD
Chinese   English 

Thermal gas mass flow meter HNF80-A

The HNF80-A Thermal Gas Flow Switch/Flow Meter is an instrument that utilizes the principle of heat conduction to measure flow. The meter utilizes the constant temperature difference method to accurately measure gas flow. It has the advantages of small size, high digitization, easy installation and accurate measurement. The fluid pipe is equipped with a heated NTC, once a fluid flows through, it will take away the heat of the NTC, the heat taken away by the NTC, the resistance value rises, the rate of rise and the fluid flow rate has a certain relationship, so it can be detected through the measurement of this resistance value, the flow rate. HNF80-A Thermal Gas Flow Switch/Flow Meter is an instrument that utilizes the principle of heat conduction to measure the flow rate. The meter utilizes the constant temperature difference method to accurately measure gas flow. It has
Small size, high degree of digitization, easy installation, accurate measurement and other advantages. The fluid pipe is equipped with a heated NTC, once the fluid flows through, it will take away the heat of the NTC, the heat taken away by the NTC, the resistance value rises, the rate of rise and the fluid flow rate has a certain relationship, so it can be detected by measuring the resistance value of the flow rate. In addition, a temperature sensor is built in to compensate for the fluid temperature or ambient temperature, so stable measurement is possible within the operating temperature range.

HNF80-A Thermal Micro Gas Mass Flow Meter (5–2000 L/min)

The HNF80-A thermal gas flow meter measures small gas flows using the constant-temperature-difference principle: a heated NTC element sits in the gas stream, and the heat carried away by flowing gas changes its resistance at a rate proportional to flow velocity. A built-in temperature sensor compensates for gas or ambient temperature changes. The integrated LCD shows both instantaneous and cumulative flow, with switch, pulse and analog outputs in one compact body — ideal for equipment-level and plant-level gas consumption monitoring.

Get a Quote

Direct Mass Flow Measurement for Small Gas Flows

The HNF80-A is an instrument that measures gas flow based on the heat-conduction principle using the constant-temperature-difference method. It offers small volume, high digitization, convenient installation and accurate measurement.

A heated NTC element is installed in the gas pipeline. Once gas flows through, it carries heat away from the NTC; the resulting resistance rise rate has a fixed relationship with flow velocity. The meter reads this resistance to determine flow. An onboard temperature sensor compensates for gas or ambient temperature drift, ensuring stable readings across the operating range.

Typical conditions: dry air, nitrogen and other clean gases; small flows from 5 to 2000 L/min; equipment integration or plant-level air consumption monitoring; when a local digital display and multiple output signals are needed.

Is HNF80-A Right for Your Application?

Choose this model when the following conditions are met:

  • Measuring medium is dry air or nitrogen and other clean, dry gases (not suitable for gas with liquid droplets, dust or corrosive components)

  • Flow range falls within 5–500 L/min (501), 10–1000 L/min (102) or 20–2000 L/min (202)

  • Fluid temperature 0–50°C, operating pressure 0–0.8 MPa

  • Local LCD display is required (instantaneous flow + switchable cumulative flow)

  • Outputs needed: PNP/NPN switch + analog (4–20mA / 1–5V) + pulse output

  • Port is Rc1/2, NPT1/2, G1/2 (501/102) or Rc3/4, NPT3/4, G3/4 (202)

Please confirm with us first if: the gas contains moisture, oil mist, dust or corrosive components; temperature is outside 0–50°C; pressure exceeds 0.8 MPa; or the measured gas is not dry air/nitrogen (flow factor must be recalibrated).

Why Choose a Thermal Gas Mass Flow Meter Here

Direct Mass Flow Measurement

The thermal principle directly reflects gas mass flow, so no additional temperature or pressure compensation is needed to obtain standard-state flow — reducing installation and conversion effort.

Small-Flow, High-Precision Digital Display

Ranging from 5 L/min, it covers equipment-level micro gas monitoring. The LCD main screen shows instantaneous flow; the sub-screen switches to cumulative flow, set values, peak/valley values and line names — no separate display instrument required.

Multiple Outputs in One Unit

A single instrument integrates switch output (PNP/NPN selectable), cumulative pulse and analog output (4–20mA or 1–5V/0–10V), connecting simultaneously to PLCs, counters and data acquisition systems.

Easy Installation, Low Straight-Pipe Requirement

Integral inline body requires only ≥8 cm straight pipe on the inlet side. The display rotates 90° for the best reading angle, and the M8 connector makes wiring quick — suitable for OEM equipment integration.

Technical Specifications

ItemSpecification
ModelHNF80-A-501 / HNF80-A-102 / HNF80-A-202
Measuring mediumDry air
Fluid temperature range0–50°C
Detection methodThermal type (constant-temperature-difference)
Rated flow range5–500 L/min (501); 10–1000 L/min (102); 20–2000 L/min (202)
Instantaneous flow setting range5–525 / 10–1050 / 20–2100 L/min
Cumulative flow range0–999,999,999 L
Minimum setting unitInstantaneous: 1 L/min; Cumulative: 1 L
Pulse conversion value1 L/pulse or 10 L/pulse (pulse width = 50 ms)
Rated pressure range0–0.8 MPa (proof pressure 1.2 MPa)
Pressure characteristic±5% F.S. (at 25°C, 0.6 MPa reference)
Power supplyDC 12–24V ±10%
Current consumption≤55 mA
Display accuracy±3% F.S.
Analog output accuracy±3% F.S.
Repeatability±1% F.S. (±2% F.S. when 0.05 s response is selected)
Temperature characteristic±5% F.S. (0–50°C, 25°C reference)
Switch outputPNP/NPN selectable, max 80 mA, NO/NC selectable, short-circuit protected
Analog outputVoltage: 1–5V / 0–10V (at 24V supply); Current: 4–20mA
Display typeLCD 3-screen: main instantaneous flow + sub cumulative/set values + unit display
Protection ratingIP65
Withstand voltageAC 250V / 1 min (between external terminals and housing)
Insulation resistance≥2 MΩ (DC 500V megohmmeter)
Operating temperature0–50°C
Storage temperature-10–60°C (no condensation, no freezing)
Operating humidity35–85% RH (no condensation)
Process connectionsRc1/2, NPT1/2, G1/2 (501/102); Rc3/4, NPT3/4, G3/4 (202)
Wetted materialsSUS304, PPS, EPDM, Si, Au, FR4
CertificationCE (EMC Directive, RoHS Directive)
WeightBody 165g; cable 100g; bracket 15g

Installation & Commissioning

Please confirm the following four items before ordering:

  1. Flow range — verify normal and maximum working flow fall within the selected range (501 / 102 / 202).

  2. Process connection — select thread type (Rc / NPT / G) and size (1/2" or 3/4").

  3. Output type — choose switch PNP/NPN, analog 4–20mA / 1–5V / 0–10V, and pulse combination per your control system.

  4. Mounting bracket & cable — choose with M8 connector (3m cable) or bare wires; optional mounting bracket.

Maintain ≥8 cm straight pipe on the inlet side and avoid abrupt pipe diameter changes at the inlet. The display unit rotates for the best reading angle. After installation, first confirm zero-flow reading, then compare with actual gas flow before commissioning. Wiring: Brown=DC(+), Blue=DC(-), White=OUT1, Black=OUT2/Analog.

Outputs & System Integration

  • Switch output (OUT1 / OUT2): PNP or NPN to PLC inputs or relays — configurable as hysteresis, upper/lower limit, cumulative output, cumulative pulse or abnormal alarm mode.

  • Analog output (OUT2): 4–20mA or 1–5V / 0–10V to PLC analog modules or data loggers for continuous flow signal transmission.

  • Cumulative pulse output: one pulse per 1 L or 10 L (50 ms width) to counters or PLC high-speed input channels for gas consumption totalization.

For OEM inquiries, please specify: controller input type, required flow units (L/min, G/min or cfm), pulse equivalent, and cable length requirements.

Typical Applications

Semiconductor Purification Gas Management

Measures high-purity process gases (nitrogen, dry air) for wire bonding, high-precision lead tension bonding and electronic component mounting equipment.

Plant-Level Compressed Air & Nitrogen Management

Monitors pneumatic component air consumption and department-level gas usage, helping identify leaks and optimize compressor station efficiency.

Automotive & Rail Transit Painting Air Supply

Provides stable air flow monitoring for spray booths and rail vehicle painting lines, ensuring consistent coating quality.

Glass & Liquid Crystal Burner Control

Used for glass furnace burner fire control, FPD handling processes and negative-ion purification gas line monitoring.

Food Packaging & Leak Detection

Compact, reliable gas flow feedback for food filling and packaging, leak inspection, CO₂ management, biochemical culture devices, arc-welding monitoring and machine-tool matching.

Information Needed for Sizing

To confirm the correct HNF80-A configuration, please provide: gas type, normal and maximum flow rate, operating pressure and temperature, thread specification (Rc / NPT / G and size), required outputs (switch PNP/NPN, analog 4–20mA / 1–5V, pulse equivalent), and whether a mounting bracket or cable is needed. If the gas is not dry air or nitrogen, please specify the gas type so the flow factor can be matched accordingly.

FAQ

What dry-air flow ranges are available?

Three models: 5–500 L/min (HNF80-A-501, 1/2" port), 10–1000 L/min (HNF80-A-102, 1/2" port) and 20–2000 L/min (HNF80-A-202, 3/4" port).

Can the display show both instantaneous and cumulative flow?

Yes. The main screen defaults to instantaneous flow; pressing the up/down key switches the sub-screen to cumulative flow, set values, peak/valley values and line names. Instantaneous and cumulative display modes can be freely toggled.

Does it provide configurable PNP or NPN switching?

Both are available. Switch output is selectable as PNP or NPN per channel; NO/NC is selectable; maximum load current is 80 mA with short-circuit protection.

How does built-in temperature compensation stabilize readings?

An integrated temperature sensor compensates for gas and ambient temperature fluctuations, so the thermal measurement stays stable across the 0–50°C operating range without external compensation.

Which port size fits the 500 or 2000 L/min range?

The 5–500 and 10–1000 L/min models use 1/2" threads (Rc1/2, NPT1/2, G1/2). The 20–2000 L/min model uses 3/4" threads (Rc3/4, NPT3/4, G3/4).

Datasheet Download

HNF80-A Thermal Gas Mass Flow Meter Datasheet (PDF)


INQUIRY

CATEGORIES

CONTACT US

Contact: HongNuo

Phone: 13840589744

Tel: 86-13840589744

Email: Guiyang.bai@honno-auto. com

Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province