Compact DIN-rail module-type ultrasonic flow and heat meter converter for panel builders, OEM equipment and system integrators. It drives the same clamp-on or insertion transducers, measures transit-time flow and calculates heat with PT100 supply/return sensors; terminals cover analog inputs, relay, analog output, power and isolated RS485 for direct PLC/DCS/SCADA connection.
The HNF100-C is a compact module-type ultrasonic flow and heat meter converter that clips onto a standard 35 mm DIN rail, built for panel builders, OEM equipment and system integrators. It drives the same clamp-on or insertion transducers as the wall-mounted version, measures transit-time flow, and calculates heat energy when PT100 temperature sensors are connected to the supply and return pipes. Wiring terminals cover temperature inputs, analog inputs, relay, analog output, power and isolated RS485, connecting directly to PLC, DCS or SCADA systems.
The ABS housing snaps onto the guide rail for batch installation in instrument boxes and distribution cabinets, with a four-button navigation menu. It suits embedded flow measurement in control cabinets, metering skids, heat-meter assemblies and remote monitoring panels, where a separate wall instrument is not wanted. No pressure loss and no pipe cutting for the clamp-on option.
Good fit: OEM equipment integration, control panel and cabinet builders, PLC/DCS/SCADA automation, heat-meter assembly and manufacturing, metering skids and packaged systems, district heating substations, energy management systems, remote monitoring and telemetry, water utilities, irrigation control, retrofit and converter replacement.
Upstream and downstream transducers exchange ultrasound alternately; the transit-time difference between the two directions is proportional to flow velocity, computed with 4-byte IEEE 754 floating-point arithmetic. Pipe dimensions, material, lining and fluid are configured through the menu; zero calibration, damping, low-flow cut-off, meter factor and 11+ segment linearisation are adjustable on site.
| Model | HNF100-C — basic modular ultrasonic flow meter / heat meter converter |
|---|---|
| Principle | Ultrasonic transit-time; 4-byte IEEE 754 floating-point arithmetic |
| Accuracy | Flowrate ±1 % (flow velocity >0.2 m/s) |
| Pipe size | DN15–DN6000 |
| Pipe material | Carbon steel, stainless, cast iron, copper, PVC, aluminum, FRP, etc. |
| Fluid | Single-phase homogeneous sound-conducting liquids: water, seawater, industrial wastewater, acid/alkali solutions, alcohol, beer, various oils |
| Medium temperature | −30…160 ℃ |
| Flow velocity | 0…±10 m/s; turbidity ≤10,000 ppm with low bubble content |
| Display | Dot-matrix backlight LCD, 6×12 Chinese or 6×24 Western characters; four-button navigation; five languages |
| Current output | One 4–20 mA channel, load 0–1 kΩ, accuracy 0.1 % |
| Pulse / OCT | One OCT pulse output, pulse width 6–1000 ms (default 200 ms), isolated |
| Relay | Channel 1 relay output; two flow alarms supported |
| Analog input | Three-channel 4–20 mA input, 0.1 % accuracy; temperature, pressure or level signals |
| Temperature input | Three-wire or four-wire PT100 for cold/heat measurement |
| Communication | Isolated RS485, MODBUS; GPRS wireless module available on request |
| Power | DC 8–36 V or AC 85–264 V (optional); dissipation 1.5 W |
| Protection | Main unit IP30; sensor up to IP68 |
| Ambient | Main unit and sensor −20…60 ℃; main unit humidity 85 % RH |
| Transducer cable | Custom twisted-pair cable, up to 50 m; RS485 transmission over 1 km |
| Code | Type | Model | Pipe size | Temperature |
|---|---|---|---|---|
| 1 | Standard clamp-on, small | S1 | DN15–DN100 | −30…90 ℃ |
| 2 | Standard clamp-on, medium | M1 | DN50–DN700 | −30…90 ℃ |
| 3 | Standard clamp-on, large | L1 | DN300–DN6000 | −30…90 ℃ |
| 4 | High-temperature clamp-on, compact | S1-HT | DN15–DN100 | −30…160 ℃ |
| 5 | High-temperature clamp-on, medium | M1-HT | DN50–DN700 | −30…160 ℃ |
| 6 | High-temperature clamp-on, large | L1-HT | DN300–DN6000 | −30…160 ℃ |
| 7 | Standard insertion | ATC-1 | DN15–DN100 | −30…90 ℃ |
| 8 | Extended insertion | ATC-1-L | DN50–DN300 | −30…90 ℃ |
| 9 | Parallel insertion | ATP-1-P | DN15–DN100 | −30…90 ℃ |
| Code | Type | Model | Pipe size | Installation |
|---|---|---|---|---|
| 1 | External clamp-on | AET-1 | ≥DN50 | No shutdown |
| 2 | Small-bore insertion | SCT-1 | ≤DN40 | Line shut down |
| 3 | Insertion | TCT-1 | ≥DN50 | Line shut down |
| 4 | Pressure insertion | PCT-1 | ≥DN50 | No shutdown |
All PT100 sensors: −40…160 ℃, three-wire or four-wire available.
| Position | Meaning |
|---|---|
| HNF100-C | Basic modular ultrasonic flow meter |
| [Sensor 1–9] | Flow transducer code from the table above |
| [DN] * [Pipe material] [Nominal pressure MPa] [Cable length m ×2] | Bore, pipe material, pressure rating and cable length pair |
| [Temp sensor 1–4] | PT100 sensor code from the table above |
Example: HNF100-C-2-5*2-200 — standard medium clamp-on sensor, 5 m cable pair, DN200.
Mount the module on a standard 35 mm DIN rail inside the cabinet; terminals connect transducers, PT100, analog inputs, relay, analog output, power and RS485.
Straight run: 10D upstream, 5D downstream, 30D from a pump outlet or half-open valve.
Use the custom twisted-pair transducer cable, kept clear of power cables; max 50 m, RS485 over 1 km.
Clamp-on sensors are fixed with steel band or wire rope and couplant; UP/DN polarity must match upstream/downstream.
Built-in data logger stores flow, heat, pressure, level and temperature totals with timed output and history query; power-off records retained.
Two alarm channels; relay can drive an external alarm or beacon.
Built-in batch controller for preset-volume dosing; 11+ segment linearisation, meter factor, damping and low-flow cut-off.
OEM and automation: control cabinets, switchgear, metering skids, packaged plants, PLC/DCS/SCADA integration.
Energy and water: heat-meter assemblies, district heating substations, water utilities, irrigation, energy monitoring and trade settlement.
Industries: water supply and drainage, metallurgy, petrochemical, hydraulic engineering, energy audit and remote telemetry.
Send: pipe OD and wall thickness, material and lining, fluid and temperature, normal and maximum flow, transducer style, heat metering sensors, outputs, communication, supply and cable length. We will confirm the transducer model and ordering code before quoting.
Does it mount on standard DIN rail?
Yes. The compact ABS housing clips onto a standard 35 mm DIN rail for batch mounting in instrument boxes and distribution cabinets; it is intended for embedded OEM integration rather than wall display.
Can the module calculate heat energy?
Yes. Connect three- or four-wire PT100 sensors to supply and return; the module computes cold and heat energy alongside flow, with heat units configurable in the menu.
Which transducers work with this compact converter?
The same S1/M1/L1 clamp-on and HT high-temperature pairs, plus ATC-1, ATC-1-L insertion and ATP-1-P parallel insertion sensors, covering DN15–DN6000.
How do RS485 and analogue outputs connect to control cabinets?
Terminals provide 4–20 mA analog output, OCT pulse, relay, three 4–20 mA analog inputs, PT100 inputs, power and isolated RS485 Modbus, wiring directly to PLC, DCS or SCADA.
What logging and batch functions are included?
The built-in logger keeps timed and historical records of flow, heat, pressure, level and temperature; two alarms and a batch controller handle preset-volume dosing, with 11+ segment linearisation.
Send the pipe size, material, fluid, temperature and required outputs. We will confirm the transducer model and ordering code before quotation.
Send us your application details »