Welcome: HongNuo (Shenyang) General Machinery Co, LTD
Chinese   English 

HNT60 Corrosion-Resistant PFA / PTFE Insertion Temperature Sensor

PFA/PTFE-jacketed insertion Pt100 sensor for corrosive media, –50 to 150 °C, Class A EN 60751, 2/3/4-wire, single/dual/triple element, 50–200 mm insertion, PTFE cable, IP67, 3.5 bar.

Corrosion-Resistant PFA / PTFE Pt100 Insertion Temperature Sensor (–50…150 °C)

The HNT60 is an insertion (plug-in) Pt100 sensor built for corrosive media. A fully fluoropolymer PFA/PTFE jacket isolates the sensing element from acids, alkalis and aggressive fluids; thanks to its structure it also suits steam and high-purity lines, semiconductor wet benches and laboratory use. The cable transition has an anti-bending device. Sensors are generally assembled to DIN EN 60751 Class A; single, dual or triple Pt100 elements and two-, three- and four-wire circuits are available.

INQUIRY

Point Temperature Measurement in Aggressive Fluid Processes

The A-grade Pt100 measures temperature through the linear resistance change of the platinum wire; the PFA/PTFE anti-corrosion sleeve keeps the element away from the corrosive medium, and the resistance signal returns over a 2-, 3- or 4-wire circuit. With a PTFE connecting cable, IP67 protection and a 3.5 bar pressure rating, it fits dosing lines, chemical baths, electroplating tanks, water treatment and CIP circuits where a stainless sleeve would corrode.

Good fit: corrosive media temperature measurement, chemical and petrochemical dosing lines, acids, alkalis and aggressive chemical fluids, semiconductor wet-processing and chemical benches, laboratory and R&D, steam and high-purity fluid lines, water treatment and effluent, pharmaceutical and fine-chemical process, electroplating and surface-treatment baths, food and beverage CIP circuits, OEM equipment with aggressive media.

Is HNT60 Suitable for Your Application?

Choose HNT60 when:

  • The medium is corrosive — acids, alkalis, salts, solvents or aggressive wash fluids — and a stainless-steel sleeve would fail.

  • Temperature is within –50…150 °C, and the duty is a point insertion measurement in a liquid, bath, line or narrow vessel.

  • You need a Pt100 resistance signal on 2-, 3- or 4-wire, single/dual/triple element, with PTFE cable and a chosen wire-end connector.

Confirm with us first when: pressure exceeds 3.5 bar, temperature exceeds 150 °C, the medium attacks fluoropolymers (strong oxidizers/hot concentrated acids), or you need a 4–20 mA / HART / Modbus transmitter output (use HNT40).

Why a Fully Fluoropolymer-Jacketed Sensor

PFA / PTFE isolation from the medium

The protective tube and cable jacket are polytetrafluoroethylene (PFA/PTFE), so wetted parts resist most acids, alkalis and organic solvents. The sleeve isolates the Pt100 element instead of coating a metal probe.

Class A accuracy, flexible wiring

Class A per EN 60751. Choose 1×, 2× or 3× Pt100 with 2-, 3- or 4-wire circuits; the 4-wire version eliminates lead-resistance error, the 3-wire compensates balanced leads, and the 2-wire suits short runs.

Configurable depth, cable and connector

Insertion depth 50 / 100 / 150 / 200 mm or custom; cable 300 mm standard, up to 50 000 mm in 500 mm increments; bare ends, ferrules, flat sockets or multi-pin connectors to order.

Technical Specifications

ModelHNT60 — Corrosion-resistant insertion Pt100 temperature sensor
Measuring range–50…150 °C
Sensing elementPt100, Class A per EN 60751
Wiring systems2-wire, 3-wire, 4-wire; single, dual or triple Pt100 element
Protective tubePFA / PTFE (polytetrafluoroethylene), Ø3.2 / 4.5 / 5 / 6 mm; custom diameter available
Connecting cablePTFE, shielded optional; ambient –50…150 °C
Insertion depth50 / 100 / 150 / 200 mm; custom length
Cable length300 mm standard; 300…50 000 mm in 500 mm increments
Wire endBare ends; ferrule connectors DIN 46228-4; flat socket 6.3 × 0.8 mm DIN 46247; multi-pin connector (type specified on order)
Pressure resistance3.5 bar
Protection ratingIP67
Product safetyCE certification; functional safety complies with IEC 61508, suitable for safety applications per IEC 61511
Anti-bending deviceFitted at the connecting-cable transition
Ordering code exampleHNT60 – C / A / 4 / L100 / B / 1

Ordering Code

Code segmentCodeDescription
Measurement plugA1 × Pt100 three-wire
B1 × Pt100 two-wire
C1 × Pt100 four-wire
D2 × Pt100 three-wire
E2 × Pt100 two-wire
F2 × Pt100 four-wire
G3 × Pt100 (one two-wire, two three-wire)
Accuracy classAClass A, EN 60751
Protective tube diameter3Ø3.2 mm
4Ø4.5 mm
5Ø5 mm
6Ø6 mm
XCustomized
Insertion depthL5050 mm
L100100 mm
L150150 mm
L200200 mm
XCustomized
Cable endABare ends
BFerrule connectors, DIN 46228 Part 4
CFlat socket 6.3 × 0.8 mm, DIN 46247
DMulti-pin connector (specify type)
Cable length1300 mm (standard)
2Specify length, 300–50 000 mm, 500 mm increments

Mechanical Dimensions

PFA connector sizes and body dimensions (mm) below. Y is the protective-tube diameter; A, B and C are the defined dimension sets for each fitting.

PFA No.SizeY (tube Ø)ABC
HNT60-F141/43.284.3342.1627.18
HNT60-F383/83.289.4144.7027.18
HNT60-F121/23.295.0047.5027.18
HNT60-F343/43.2112.7856.3934.29
HNT60-F113.2137.1668.5841.40

image.png

Installation and Wiring

Insert the sensor so the tip reaches the active temperature zone of the bath or line; keep the insertion depth ≥ 8 × tube diameter where possible. Do not bend the cable near the anti-bending transition. Choose the wire end to match your input: bare ends for direct termination, ferrules for screw terminals, flat sockets or multi-pin connectors for plug-in panels. For long cable runs, prefer the 4-wire circuit to avoid lead-resistance error.

Typical Applications

  • Chemical and dosing: acids, alkalis and aggressive fluid lines and batch tanks.

  • Semiconductor and laboratory: wet benches, chemical baths, R&D and narrow lab vessels.

  • Surface treatment: electroplating and surface-treatment bath monitoring.

  • Water and pharma: effluent, water treatment, fine-chemical and CIP circuits.

  • OEM aggressive-media equipment: packaged machines where stainless probes corrode.

What to Send Us for Selection

Send: medium (concentration and composition), process temperature and pressure, vessel/line dimensions and required insertion depth, element count and wiring (2/3/4-wire), cable length, and the wire-end or connector type. We will confirm the PFA/PTFE sleeve suitability and the final order code before quoting.

Frequently Asked Questions

Which jacket diameters are available?

PFA/PTFE protective tube Ø3.2, Ø4.5, Ø5 and Ø6 mm; other diameters on request.

Which jacket suits strong acids and alkalis?

The PFA/PTFE fully fluoropolymer sleeve resists most acids, alkalis and organic solvents. Send us the exact medium, concentration and temperature so we can confirm compatibility against the 3.5 bar and 150 °C limits.

How does a fluoropolymer-wrapped Pt100 resist corrosion in a chemical bath?

The PFA/PTFE sleeve isolates the Pt100 element from the corrosive medium; only the fluoropolymer wets the fluid, so the platinum element and leads are not exposed to attack.

What insertion depth suits a narrow laboratory vessel?

Depths 50, 100, 150, 200 mm or custom; match the depth to the vessel so the tip sits in the active liquid zone without touching the bottom or wall.

Can four-wire wiring reduce cable resistance error over long distances?

Yes. The 4-wire circuit eliminates lead-resistance error; the 3-wire compensates balanced leads, while the 2-wire carries lead resistance into the reading and is best kept short.

Datasheet Download

HNT60 Corrosion-Resistant PFA/PTFE Pt100 Sensor Datasheet (PDF) — view all product manuals on our Download page »

Need Us to Check the Application?

Send us the medium, temperature, pressure and required depth. We will confirm fluoropolymer compatibility, wiring and the order code before we quote.

Send us your application details »


INQUIRY

CATEGORIES

CONTACT US

Contact: HongNuo

Phone: 13840589744

Tel: 86-13840589744

Email: Guiyang.bai@honno-auto. com

Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province