Smart temperature transmitter, –50 to 400 °C, 4–20 mA / HART / Modbus RTU RS485, optional backlit LCD, ±0.5% URL, four-level surge protection, IP67, Ex d IIC T6 Gb, for chemical, petrochemical, power plant, pipeline and tank measurement.

HNT40 Intelligent Temperature Transmitter with HART & Modbus RTU (–50…400 °C)

The HNT40 is a smart temperature transmitter built on a signal-transmission module with dedicated integrated circuits and surface-mount technology. An optional LCD module with built-in backlight and push-button operation lets you read and configure the transmitter on site. The integrated transient-voltage-resistant terminal block meets four levels of surge immunity — 2000 V differential-mode and 4000 V common-mode — for reliable operation in harsh surge-voltage environments. It covers –50…400 °C with a 100 °C minimum span, and offers 4–20 mA, 4–20 mA + HART and Modbus RTU / RS485 outputs.

INQUIRY

Smart, Configurable Temperature Measurement for Process Loops

Unlike a basic RTD or thermocouple sensor, the HNT40 transmits a conditioned, calibrated signal over a digital or analog loop. Set the lower and upper range values (LRV / URV) through the backlit LCD or a HART configuration tool; the span can be expressed in °C, °F or K. The 4–20 mA loop drives a standard analog card, the HART variant carries digital configuration and diagnostics on the same two wires, and the Modbus RTU / RS485 variant shares temperature data directly with a PLC or DCS over a bus run up to 1000 m.

Good fit: pipeline and tank process temperature, hazardous-area measurement (Ex d IIC T6 Gb), chemical and petrochemical process control, power generation and utilities, HART-enabled smart instrument loops, Modbus RTU / RS485 DCS and PLC integration, plants with high surge-voltage environments, heat exchangers and reactors, OEM skids and packaged equipment, remote temperature monitoring, energy and environmental process monitoring, general industrial automation.

Is HNT40 Suitable for Your Application?

Choose HNT40 when:

  • Process temperature is within –50…400 °C, with a minimum calibrated span of 100 °C.

  • You need a smart transmitter with local LCD reading, on-site LRV/URV configuration, or digital diagnostics — not just a raw sensor signal.

  • The control system expects 4–20 mA, 4–20 mA + HART, or Modbus RTU / RS485, and the loop needs surge protection near motors and control cabinets.

  • The mounting point is a pipeline, tank or process connection, with threaded or flange fitting.

  • The area is a classified hazardous location requiring Ex d IIC T6 Gb protection.

Confirm with us first when: the duty exceeds 400 °C (use HNT30 armored thermocouple), the medium is strongly corrosive (check HNT60 PFA/PTFE), the measurement is non-contact infrared (HNT50), or you need a compact plug-style sensor without a transmitter head (HNT10 / HNT20).

Why a Smart HART / Modbus Transmitter — Not the Alternatives

Three output choices for your control system

Pick 4–20 mA two-wire for ordinary analog loops; 4–20 mA + HART when you want digital range configuration, diagnostics and remote monitoring on the same two wires; Modbus RTU / RS485 (four-wire) when the PLC or DCS reads temperature over a bus rather than a point-to-point analog channel.

Local LCD with push-button setup

The optional backlit LCD shows temperature, current and device status on site. LRV and URV are set through the push buttons without a separate hand-held communicator; the housing keeps the display in service between –20 and 70 °C.

Surge-resistant terminal block

The integrated transient-voltage-resistant terminal block passes four surge-immunity levels, 2000 V differential-mode and 4000 V common-mode. This protects the loop from switching transients near motors, variable-speed drives and industrial control cabinets.

Explosion-proof housing for classified areas

Ex d IIC T6 Gb rated housing, IP67 protection, suitable for classified chemical, petrochemical and power-plant hazardous areas. Verify the zone, gas group and T-group with our engineers before selection.

Technical Specifications

ModelHNT40 — Intelligent (smart) temperature transmitter
Measuring range–50…400 °C; minimum calibrated span 100 °C. LRV and URV must stay within the range limits, with minimum span ≤ URV − LRV ≤ range upper limit. Units can be °C, °F or K; other ranges on request.
Reference accuracy±0.5 % of upper range limit (URL)
Annual stabilityBetter than 0.05 % URL or 0.1 °C / year, whichever is greater, under verification conditions
Ambient temperature effect≤ ±0.005 % URL / °C (reference 22 °C)
Power supply effect≤ ±0.01 % URL / V (reference 24 V, data referred to full-range 20 mA output)
Load effect≤ ±0.02 % URL / 100 Ω (referred to full-range 20 mA output)
VibrationIEC 60068-2-6, 4 g / 2…100 Hz
Insulation resistance≥ 20 MΩ at 100 VDC under reference conditions
Output signal4–20 mA (two-wire); 4–20 mA + HART (two-wire); Modbus RTU / RS485 (four-wire); other outputs custom
Power supplyStandard 10…30 VDC; HART 16.5…55 VDC with 250 Ω load during communication; RS485 12…32 VDC. Load 0…2119 Ω working state, 250…600 Ω for HART communication; transmission distance < 1000 m; power consumption ≤ 500 mW @ 24 VDC, 20.8 mA
Response time≤ 10 s in water at 0.4 m/s with Ø6 probe; total damping time constant = sum of electronic circuit and thermal-conductivity components. Sleeve response times t50 / t90 depend on diameter and tube form; figures exclude transmitter response time.
Operating temperature–40…85 °C; with integrated LCD –20…70 °C
Storage temperature–40…100 °C; with integrated LCD –40…85 °C
Humidity0…95 % RH
Protection ratingIP67
Explosion-proofEx d IIC T6 Gb (consult our engineer for details)
Probe diameterØ6, Ø8, Ø10, Ø12, Ø16 mm protective tube
Probe length L25 / 50 / 80 / 100 mm; custom length available
Sensor typeA economical; B industrial
Mechanical connectionThread: British G, metric M, American N; flange: national standard FG, American standard FA; DN25 / DN50 flanges per HG/T 20592-2009
Minimum insertion depth≥ 8 × protective sleeve outer diameter; probe end reaches or exceeds the pipeline axis
Test standardGB/T 30121 / IEC 60751; reference conditions: range starting from zero, 4–20 mA analog output, terminal fine-tuned to set value
Ordering code exampleHNT40 – B / 0…150 °C / 50 / A8 / G / MH / 1

Ordering Code

Build the order code from left to right. Send us the full code — or just your application parameters and we will assemble it for you.

Code segmentCodeDescription
Sensor typeAEconomical
BIndustrial
Temperature rangeXState the required range, e.g. 0…150 °C
Probe length L25Probe length L = 25 mm
50Probe length L = 50 mm
80Probe length L = 80 mm
100Probe length L = 100 mm
XCustom length
Probe diameterA6Ø6 mm protective tube
A8Ø8 mm protective tube
A10Ø10 mm protective tube
A12Ø12 mm protective tube
A16Ø16 mm protective tube
Mechanical connectionGBritish standard thread
MMetric standard thread
NAmerican standard thread
FGNational standard flange
FAAmerican standard flange
Output signalM4–20 mA output
MH4–20 mA output with HART
XCustom output
Explosion-proof0No explosion-proof required
1Explosion-proof required

Mechanical Dimensions

HNT40 is supplied in a threaded strip-display version (C) and a flange strip-display version (C), with the transmitter housing, cable glands, fitting and protective sleeve shown in the dimension drawings below.

image.png

Installation and Configuration

Confirm these items before ordering:

  1. Process temperature and span — top and normal temperature, and the required LRV / URV; minimum span 100 °C.

  2. Output and system — 4–20 mA, 4–20 mA + HART, or Modbus RTU / RS485; PLC / DCS input type and load resistance.

  3. Fitting and probe — thread or flange, probe diameter and length; insertion ≥ 8 × sleeve OD, tip at or beyond the pipe axis.

  4. Explosion-proof and sensor grade — Ex d IIC T6 Gb required or not; A economical or B industrial.

Mount the probe so the tip reaches the active temperature zone of the pipe or tank. Tighten on the fitting hex, never on the sleeve or probe. For HART loops, keep the 250 Ω load in the communication circuit; for RS485 bus, observe the bus topology, termination and the 1000 m distance limit. Configure LRV / URV through the LCD push buttons or a HART configurator, and verify the output against a reference thermometer before commissioning.

Outputs and System Integration

  • 4–20 mA (M): two-wire analog loop, 10…30 VDC supply, load 0…2119 Ω; standard analog card connection.

  • 4–20 mA + HART (MH): two-wire HART loop, 16.5…55 VDC, 250…600 Ω HART load; digital range setup, diagnostics and remote monitoring on the same wires.

  • Modbus RTU / RS485: four-wire bus, 12…32 VDC; shares temperature data with PLC / DCS over RS485, distance < 1000 m.

For OEM / engineering / project enquiries, send us: medium, top and normal temperature, required output, controller input type, fitting and probe length, whether Ex-rated, and any surge or vibration conditions. We will confirm the sensor grade, output code and final order code before quotation.

Typical Applications

Chemical and petrochemical process control

Reactor, heat-exchanger and pipeline temperature loops in classified areas, where HART diagnostics and the Ex d housing fit plant DCS and maintenance routines.

Power generation and utilities

Boiler auxiliary circuits, cooling and heating loops, compressed-air and water systems, monitored over 4–20 mA or RS485 into plant control.

Pipeline and tank measurement

Storage tanks, transfer lines and process piping where a local LCD reading and on-site span setting reduce the need for a separate communicator visit.

Surge-prone industrial environments

Loops near motors, variable-speed drives and control cabinets, where the four-level surge-resistant terminal block protects the transmitter and analog card.

OEM skids and packaged equipment

Chillers, compressors, packaged process skids and test rigs, with Modbus RTU / RS485 integration into the skid controller or a 4–20 mA analog loop.

What to Send Us for Selection

Send the following with your enquiry: process medium, maximum and normal operating temperature, required LRV / URV span, output signal (4–20 mA, HART or Modbus RTU), controller input type, fitting or flange size, probe diameter and length, explosion-proof requirement, and any vibration, surge or corrosive conditions. For hazardous-area duties, note the zone classification and gas group.

Frequently Asked Questions

Does this transmitter support HART?

Yes. Order the MH code for a 4–20 mA + HART two-wire transmitter. HART runs on the same two wires as the analog current, with 16.5…55 VDC supply and a 250…600 Ω communication load, supporting remote range setup and diagnostics.

Can Modbus RTU share temperature data over RS485?

Yes. The RS485 / Modbus RTU variant is a four-wire bus output on 12…32 VDC, suitable for PLC or DCS bus integration; bus runs stay under 1000 m. It does not share the two-wire HART loop.

How are lower and upper range values configured through the LCD?

With the optional backlit LCD, set LRV and URV through the push buttons on the housing. The LRV and URV must stay within the –50…400 °C range, and URV − LRV must be at least the 100 °C minimum span. HART configuration can also be done with a HART communicator.

Which power supply is required for two-wire 4–20 mA operation?

Standard two-wire 4–20 mA runs on 10…30 VDC. The HART variant needs 16.5…55 VDC with the 250 Ω communication load; the RS485 variant needs 12…32 VDC. Working load is 0…2119 Ω, 250…600 Ω for HART communication.

How does surge protection improve reliability near motors and control cabinets?

The integrated transient-voltage-resistant terminal block passes four surge-immunity levels — 2000 V differential-mode, 4000 V common-mode — clamping switching transients from motors, drives and contactors so the transmitter and analog card are not damaged by line surges.

Datasheet Download

HNT40 Intelligent Temperature Transmitter with HART & Modbus RTU Datasheet (PDF) — view all product manuals on our Download page »

Need Us to Check the Application?

Send us the medium, top temperature, required output, fitting and probe length. We will confirm the sensor grade, output code and whether an Ex housing is needed before we quote.

Send us your application details »


INQUIRY

CATEGORIES

CONTACT US

Contact: HongNuo

Phone: 13840589744

Tel: 86-13840589744

Email: Guiyang.bai@honno-auto. com

Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province