Intelligent industrial-grade vortex flow meter based on the Karman vortex street phenomenon: a triangular bluff body sheds alternating vortices whose frequency is proportional to fluid velocity, giving highly stable pulse output that is linear to actual flow with no zero drift. Measures VOLUME and MASS flow of steam (saturated steam with dryness above 85% counts as single-phase; superheated steam supported), compressed air, general gases and liquids. Nominal sizes DN15–DN400 full-bore (clamp, flange or thread), insertion type DN200–DN1500 for large ducts, small DN6–DN12 on request. Accuracy: liquid ±0.5 / ±1.0 / ±1.5%, gas additionally ±2.5%; standard rangeability 8:1–20:1, extended ≥30:1. Process temperature −40…+350 ℃ standard (up to +500 ℃ on request); pressure rating ≤2.5–4.0 MPa standard (up to 45 MPa on request). Local display shows instantaneous flow, totalized flow and flow percentage. Outputs: two-wire 4–20 mA, pulse/frequency 2–3000 Hz, optional HART, Modbus RTU (RS485) and wireless remote transmission; battery (3.6 V) option. Intrinsically safe Ex ia IIC T1–T4 Ga; IP65 standard, IP68 submersible; body and wetted parts 304 stainless steel (316 on request). Split version allows amplifier/sensor separation up to 15 m; options include temperature-flow integrated and temperature-pressure-flow integrated types
The HNF40-B works on the Karman vortex street principle: as the medium passes a triangular bluff body, alternating vortices are shed at a frequency proportional to flow velocity. A converter processes the signal to display instantaneous and totalised flow and communicate with control systems.
One instrument measures VOLUME and MASS flow of steam, gas and liquid with no moving parts, zero drift and long-term stability. Full-bore versions cover DN15–DN300 and insertion versions cover DN200–DN1500. Medium temperature goes up to +350 °C, and the amplifier can be separated from the sensor up to 15 m. Outputs include 4–20 mA, pulse, HART and RS485, with options for temperature-flow integration, temperature-pressure-flow mass compensation, explosion-proof and battery-powered versions.
Media: Steam / Gas / Liquid Size: DN15 – DN1500 (insertion) Accuracy: ±0.5 – 2.5% Medium temp: −40 to +350 °C Outputs: 4-20mA / Pulse / HART / RS485
Applications: saturated & superheated steam metering, compressed air monitoring, natural gas & general gas flow, industrial liquid measurement, boiler & energy monitoring, utility steam distribution, chemical & petrochemical plants, power plants, food & beverage steam lines, pharmaceutical utilities, HVAC & process steam, water & wastewater.
Select this model when all of the following conditions are met:
You need one instrument covering steam, gas or liquid flow – both volumetric and mass flow.
Pipe size is within DN15–DN300 (full-bore) or DN200–DN1500 (insertion).
Medium temperature is high (up to +350 °C) and process pressure does not exceed 4.0 MPa.
4–20 mA, pulse, HART or RS485 outputs are required for PLC / DCS / SCADA integration.
The site has explosion-proof requirements, or the metering loop needs SIL functional safety.
Remote (split) mounting, battery power, wireless transmission or temperature-pressure compensated mass flow is required.
Please consult us first if: the medium is heavily contaminated or oily, pipe size exceeds DN1500, pressure exceeds 4.0 MPa, temperature exceeds +350 °C, flow is pulsating or vibration is severe, or custody-transfer high-accuracy calibration is required.
The same meter measures superheated steam, saturated steam (dryness above 85% treated as single-phase), compressed air, general gases and liquids. With temperature-pressure compensation options it directly outputs standard volumetric or mass flow, eliminating secondary calculation.
Rangeability of 8:1–20:1 with extended ranges available. No moving parts; the pulse output is linear to actual flow with zero drift, giving stable long-term performance and low maintenance.
Full-bore versions offer flange, wafer and threaded connections (DN15–DN300); insertion versions cover DN200–DN1500. Ball-valve insertion versions allow hot-tap removal without shutting down the line, cutting large-line installation and maintenance cost.
4–20 mA (active/passive), pulse (active/passive), HART and RS485 Modbus outputs. CE and SIL marked; functional safety per IEC 61508, suitable for IEC 61511 safety-related applications.
| Model | HNF40-B Smart Industrial Vortex Flow Meter |
|---|---|
| Principle | Karman vortex street; shedding frequency from triangular bluff body |
| Measured media | Steam (saturated/superheated), gases (compressed air/natural gas/general), liquids |
| Full-bore sizes | DN15 – DN300 (flange / wafer / thread) |
| Insertion sizes | DN200 – DN1500 (standard / reduced / dual-sensor / ball-valve insertion) |
| Liquid flow range | 0.3 – 1800 m³/h (full-bore); 40 – 31000 m³/h (insertion) |
| Gas flow range | 2.8 – 8000 m³/h (full-bore); 400 – 410000 m³/h (insertion) |
| Steam flow range | 60 kg/h – 40 t/h (full-bore); 11.2 – 2050 t/h (insertion) |
| Accuracy | Liquid ±0.5 / ±1.0 / ±1.5%; gas additionally ±2.5% |
| Max. process pressure | 4.0 MPa (PN10 / PN16 / PN25 options) |
| Medium temperature | −40 … +350 °C |
| Ambient temperature | −20 … +55 °C |
| Wetted materials | 304 stainless steel (316 and other materials by agreement) |
| Transmitter housing | Cast aluminium AlSi10Mg (coated) |
| Display & operation | 4-line backlit display, external touch keys; local configuration & remote display option; split version up to 15 m |
| Output signals | 4–20 mA (active/passive); pulse frequency (active/passive); 4–20 mA + HART; 4–20 mA + RS485 Modbus |
| Power supply | DC 12 V; DC 24 V; 220 VAC; 3.6 V lithium battery dual supply (wireless) |
| Hazardous area | Non-ex / flameproof / intrinsically safe versions available |
| Functional options | Standard; temperature-flow integrated; temperature-pressure-flow integrated (mass flow); wireless remote monitoring (non-ex) |
| Approvals & standards | CE, SIL; functional safety per IEC 61508 for IEC 61511 safety applications |
Confirm 4 items before ordering:
Medium (steam/gas/liquid), normal and maximum flow – to select size and accuracy class.
Pipe size and connection type (flange / wafer / insertion) and pressure rating PN10/16/25.
Medium temperature and operating pressure – to determine standard/high-temperature version and T-P compensation.
Output signal, power supply, Ex rating, and whether split / wireless / mass flow is needed.
Allow sufficient straight pipe upstream (typically ≥15–20D) and downstream (≥5D), avoiding pump discharge, valves and strong vibration. Align the flow arrow. For split mounting, keep the sensor-to-amplifier cable within 15 m. After power-up, use the 4-line display and touch keys to configure medium, units, range and outputs; confirm zero reading at no flow before commissioning.
4–20 mA output (active/passive): transmits instantaneous flow to PLC, DCS or chart recorders for process regulation and data acquisition.
Pulse/frequency output (active/passive): linear to actual flow with zero drift; direct connection to PLC high-speed counters or totalisers for cumulative and auxiliary custody metering.
HART & RS485 Modbus: supports remote configuration, data reading and multi-instrument networking for SCADA, energy and asset management platforms.
T-P compensation & wireless versions: temperature-pressure-flow versions directly output mass flow; 3.6 V battery + wireless versions suit outdoor and unpowered pipelines.
For OEM and system integration projects, please specify size, connection, medium conditions, output protocol, Ex rating and whether mass flow or wireless transmission is required.
Measures flow at boiler outlets, headers and steam distribution lines; with T-P compensation it outputs mass flow directly, supporting energy accounting and cost allocation.
Measures compressed air, natural gas and general industrial gas flow to monitor air-station efficiency and detect pipeline leakage, supporting energy-saving retrofit decisions.
Measures clean process gases and liquids on chemical and petrochemical lines; flameproof or intrinsically safe versions are available for hazardous-area installation.
Used for steam distribution in power plants, water treatment and cooling circuits, as well as pharmaceutical and food & beverage utility steam and HVAC process steam.
DN200–DN1500 gas, steam and liquid lines use insertion mounting; ball-valve insertion versions allow sensor removal without line shutdown, reducing cost on large pipelines.
To confirm the correct HNF40-B configuration, please provide: medium name (steam/gas/liquid and composition), nominal diameter and connection type, operating temperature & pressure, typical and maximum flow, accuracy class, output signal type, power supply, explosion-proof requirement, whether T-P compensated mass flow is needed, and whether split/wireless remote transmission is required. If necessary we will request additional details on straight pipe, vibration and hazardous-area classification.
Yes. Based on the Karman vortex principle, one meter measures superheated steam, saturated steam, compressed air, general gases and liquids, and can output mass flow with T-P compensation.
Full-bore covers DN15–DN300 and insertion covers DN200–DN1500. For large air ducts, steam and water lines, choose insertion; select ball-valve insertion when sensor replacement must occur without shutdown.
Yes. The 4-line backlit display shows instantaneous flow, totalised flow and flow percentage simultaneously, with local touch-key configuration and remote display option.
The temperature-pressure-flow integrated version compensates in real time using the medium density formula, directly outputting standard volumetric or mass flow without secondary lookup tables or conversion.
Choose insertion when pipe size exceeds DN300, where full-bore cost is too high or installation is restricted (DN200–DN1500); choose ball-valve insertion when sensor replacement must happen without process shutdown.
HNF40-B Smart Industrial Vortex Flow Meter Datasheet (PDF)
Insert the download link here after uploading the PDF to your website.
Send us medium, pipe size, temperature/pressure, flow range, output type and Ex rating, and we will confirm whether HNF40-B is suitable and provide a selection recommendation before quotation.
Submit your application details »Contact: HongNuo
Phone: 13840589744
Tel: 86-13840589744
Email: Guiyang.bai@honno-auto. com
Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province