Compact inline vortex flow meter designed for low-flow liquid monitoring from 0.4 to 400 L/min. Based on the vortex-shedding principle with no moving parts, it is unaffected by pipeline static pressure, needs no on-site calibration or debugging, and is essentially maintenance-free. Five-point flow linearization delivers stable, repeatable readings, and the strong anti-pollution design suits both clean and lightly contaminated liquids. Optional built-in temperature measurement (0–100 ℃) turns it into a flow + temperature monitor; models without temperature function are also available. Wetted parts in POM or SUS304 stainless steel, pressure rating 10 bar (16 bar max), medium temperature −20…100 ℃; process connections threaded G/R 3/8″–1-1/2″; supply 18–30 VDC. Outputs: three-wire 4–20 mA linear to flow (and temperature where fitted, max load 500 Ω), user-adjustable pulse/frequency up to 1 kHz (e.g. 1 pulse/litre or 1 litre/pulse), RS485 available on request. Typical duties: cooling water and circulating water monitoring, antifreeze and sprinkler systems, sewage protection lines, and flow monitoring of organic and inorganic solutions.
The HNF40-A is a compact inline vortex flow sensor based on the Karman vortex street principle. A triangular bluff body sheds alternating vortices whose frequency is proportional to flow velocity – there are no moving parts and the measurement is unaffected by pipeline static pressure.
Simple construction, maintenance-free, and requiring no on-site calibration or commissioning. Five-point flow linearisation delivers stable, repeatable readings, and the anti-pollution design suits both clean and lightly contaminated liquids. An optional built-in temperature measurement (0–100 °C) turns it into a combined flow + temperature monitor. Typical duties include cooling water, circulating water, antifreeze, sprinkler and sewage protection circuits.
Flow range: 0.4–400 L/min No moving parts Outputs: 4–20 mA / pulse / RS485 Wetted: POM / SUS304 Temperature measurement optional
Applications: cooling water & circulating water monitoring, critical water flow detection, organic/inorganic solution monitoring, antifreeze protection, sprinkler systems, sewage protection lines, semiconductor cooling, machine-tool cooling, heat-treatment equipment, process fluid monitoring.
Select this model when all of the following conditions are met:
The measured medium is a low-flow liquid within 0.4–400 L/min (6 range scales available).
The pipeline uses threaded connections from 3/8" to 1-1/2" female thread (G or R).
4–20 mA analogue or user-settable pulse/frequency output is required for PLC or totaliser connection.
A no-moving-parts, maintenance-free, no-field-calibration design is preferred to reduce setup and lifecycle cost.
The medium is water or lightly contaminated liquid / organic-inorganic solution, and ±3% F.S. accuracy is acceptable.
Temperature monitoring is required – the optional version measures both flow and temperature in one sensor.
Please consult us first if: the medium carries many hard solids or is highly viscous, temperature is outside −20…100 °C, line pressure exceeds 16 bar, gas or steam measurement is needed, or higher accuracy class (e.g. ±0.5%) is required.
Based on the Karman vortex principle with no turbine, bearing or moving component inside. No wear, no jamming, and readings are unaffected by pipeline static pressure fluctuations for long-term stable operation.
Factory-calibrated with five-point flow linearisation. Simply thread it in and power up – no field calibration or debugging required, significantly shortening equipment integration and retrofit time.
Six ranges – 0.5–4, 2–16, 5–40, 10–100, 50–250, 100–400 L/min – cover low-flow duties from micro-dosing to medium flow liquid applications.
Three-wire 4–20 mA linear output and pulse/frequency up to 1 kHz with user-settable pulse scaling (e.g. 1 pulse/L or 1 L/pulse); RS485 optional for easy integration with various control systems.
| Model | HNF40-A Small Vortex Flow Sensor |
|---|---|
| Principle | Karman vortex street; vortex frequency from triangular bluff body |
| Measured media | Water and low-flow liquids, organic/inorganic solutions |
| Flow range (liquid) | 0.4–400 L/min in 6 scales: 0.5–4 / 2–16 / 5–40 / 10–100 / 50–250 / 100–400 L/min |
| Accuracy | Flow ±3.0% F.S.; Temperature ±1.0 °C (with temperature version) |
| Repeatability | < 2.0% |
| Wetted materials | POM or SUS304 stainless steel |
| Process connection | Female thread G or R, sizes 3/8" – 1-1/2" |
| Pressure rating | 10 bar (max. 16 bar) |
| Medium temperature | −20 … 100 °C |
| Ambient temperature | −10 … 65 °C |
| Temperature measurement (optional) | 0–100 °C, accuracy ±1.0 °C |
| Power supply | 18–30 VDC |
| Signal output | 3-wire 4–20 mA (max. load 500 Ω); pulse/frequency up to 1 kHz with user-settable pulse scaling; RS485 optional |
| Electrical connection | Direct cable (2 m std., 5 m / 10 m options) or M8-4Pin aviation plug |
| Mounting | Threaded inline; optional mounting bracket |
Confirm 4 items before ordering:
Normal and maximum flow rate – to select the correct range scale and keep the operating point in the optimal band.
Pipe thread type and size (G or R, 3/8"–1-1/2") – to confirm connection compatibility.
Whether temperature measurement is required, output type and pulse scaling.
Electrical connection (direct cable or M8 plug) and required cable length.
Align the flow direction with the arrow on the body and prefer straight pipe runs for stable vortex signals. After wiring, no on-site calibration is required – the 4–20 mA and pulse signals correspond directly to factory calibration. To change pulse scaling, set pulses per litre (or litres per pulse) per the user manual and verify totalisation before commissioning.
4–20 mA analogue output: linear to flow (and temperature where fitted), user-configurable within the measuring range, max. load 500 Ω, direct to PLC analogue modules or recorders.
Pulse / frequency output: up to 1 kHz, user-settable pulse scaling (e.g. 1 pulse/L or 1 L/pulse) for totalisers and batching control.
RS485 communication (optional): supports digital networking for remote monitoring and multi-sensor management.
Temperature version: one sensor outputs both flow and temperature signals, saving pipe penetrations and installation space.
For OEM volume projects, please specify flow range, thread size, output type, temperature requirement and cable length with your enquiry so we can match the correct configuration.
Monitors flow in equipment cooling loops and industrial circulating water systems, triggering alarm or interlock on abnormal flow to protect equipment from overheating.
Used with antifreeze protection, sprinkler and fire-protection systems to monitor water flow and ensure critical circuits operate in low-temperature or fire conditions.
Suitable for sewage protection lines and low-flow monitoring of organic and inorganic solutions; the anti-pollution design ensures long-term stable readings.
Used in semiconductor equipment (etching, grinding, slicing, CVD) and machine-tool water-soluble coolant circuits; compact body fits space-constrained machine internals.
Provides flow monitoring and data acquisition on heat-treatment equipment and process fluid lines to improve process stability.
To confirm the correct HNF40-A configuration, please provide: normal and maximum flow rate, pipe thread type & size (G/R), medium name & temperature, whether temperature measurement is needed, output type (4–20 mA / pulse / RS485), pulse scaling requirement, electrical connection & cable length, and wetted material preference (POM / SUS304). If necessary we will request additional details on line pressure and mounting orientation.
The smallest range scale is 0.5–4 L/min; the overall product covers 0.4–400 L/min for low-flow liquid measurement, depending on the selected range code.
Yes. The anti-pollution construction is designed not only for clean water but also for sewage protection lines and lightly contaminated organic/inorganic solutions.
No. The HNF40-A works on the Karman vortex principle, deriving flow from the vortex frequency produced by a triangular bluff body. There is no turbine, no bearing and no moving part inside.
Pulse frequency goes up to 1 kHz and the user can set the pulses per litre (e.g. 1 pulse/L) or litres per pulse (e.g. 1 L/pulse) within the range, for easy interfacing with totalisers and batching controls.
Process connections are female G or R threads from 3/8" to 1-1/2". The six flow range codes map to different thread sizes; match the range and thread to your actual flow and pipe bore.
HNF40-A Small Vortex Flow Sensor Datasheet (PDF)
Insert the download link here after uploading the PDF to your website.
Send us flow range, thread size, medium temperature/pressure, output type and whether temperature measurement is required, and we will confirm whether HNF40-A is suitable and provide a selection recommendation before quotation.
Submit your application details »Contact: HongNuo
Phone: 13840589744
Tel: 86-13840589744
Email: Guiyang.bai@honno-auto. com
Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province
We chat