All-in-one on-pipe ultrasonic flow and heat meter with IP68 host, submersible to 2 m; terminal compartment silicone-sealed after wiring. Clamp-on, insertion or pipe-section transducers in single/dual/four channel; PT100 supply/return heat metering; analog, OCT, relay, frequency and RS485 connect directly to the control system, with no wall unit or long cable run.

HNF100-G Integrated IP68 Ultrasonic Flow Meter

The HNF100-G is an all-in-one ultrasonic flow and heat meter: the converter mounts directly on the pipe, on a wall or even underwater. The host is rated IP68 and can operate submerged to 2 m; after wiring, the terminal block is filled with the supplied silicone to make the mainboard watertight. No separate instrument panel or cable run to a wall unit is required.

INQUIRY

Sealed for Wet and Remote Sites

The electronics are sealed together with the pipe assembly, which suits underground pits, meter chambers, flooded manholes, utility tunnels and remote sites where a conventional wall-mounted converter would be exposed. The local display runs the 100+ menu system for pipe size, material, lining, fluid, transducer type and mounting, units, damping, low-flow cut-off, zero calibration, meter factor and 11+ segment linearisation.

Good fit: underground pits and meter chambers, flooded manholes and utility tunnels, water supply and distribution networks, irrigation and agriculture, groundwater and well monitoring, district heating and cooling, HVAC and building services, industrial water and cooling circuits, temporary or remote metering sites, mining and construction water management, sewage and drainage, retrofit where no panel space exists.

Working Principle

Upstream and downstream transducers exchange ultrasound alternately; the transit-time difference between the two directions is proportional to flow velocity. Single, dual or four channels average the velocity profile on large or disturbed mains. Pipe data and fluid properties are entered in the menu; the converter computes transducer spacing and V/Z method.

Technical Specifications

ModelHNF100-G — integrated (all-in-one) ultrasonic flow meter / heat meter
ProtectionHost IP68, submersible to 2 m; terminal compartment silicone-sealed after wiring; transducer IP68
PrincipleUltrasonic transit-time; single, dual or four channel
AccuracyOne-channel ±1 %; two- / four-channel ±0.5 %; flow velocity ≥0.3 m/s one-/two-channel, ≥0.1 m/s four-channel
Pipe sizeDN15–DN6000
Transducer styleClamp-on, insertion or pipe-section; standard or high-temperature body
FluidWater, seawater, industrial sewage, various oils and other single-uniform sound-conducting liquids
Medium temperature−30…90 ℃ standard; −30…160 ℃ high-temperature
Current output4–20 / 0–20 / 0–4–20 mA, accuracy better than 0.1 %
OCT pulseIsolated open-collector, DC 60 V / 100 mA; pulse width 6–1000 ms
Relay / frequencyRelay AC 125 V / DC 28 V, 1 A; frequency and cumulative pulse output; two alarms
Analog input4–20 mA current input, usable as a data collector for temperature, pressure or level
Temperature inputThree-wire or four-wire PT100 on supply and return for heat metering
CommunicationIsolated RS485, MODBUS ASCII/RTU, M-BUS
Data and controlBuilt-in data logger with timed output and history query; batch controller; 11+ segment linearisation, meter factor, damping, low-flow cut-off, zero calibration
Power supplyDC 24 V; optional AC 85–264 V waterproof power adapter
Ambient / cableConverter −20…60 ℃; cable length and type confirmed per configuration

Transducer Options

StyleUsePipe size
Clamp-onExisting pipe, no shutdown; standard or high-temperature bodyDN15–DN6000
InsertionLarge bore, lined or buried pipe, or a surface that cannot be clampedDN50–DN6000
Pipe-sectionHigh accuracy or special fluid conditions; specified on requestPer configuration

How to Specify

ItemOptionsNotes
ChannelsSingle / dual / four channelMulti-channel for large pipes and disturbed flow
TransducerClamp-on / insertion / pipe-section; standard or high temperatureChoose by pipe OD, fluid temperature and access
Heat meteringNot fitted | PT100 pair, 3- or 4-wireSupply and return sensors for cold/heat energy
Outputs4–20 / 0–20 / 0–4–20 mA, OCT, relay, frequency / cumulative pulseConfigured in the menu
CommunicationIsolated RS485 Modbus ASCII/RTU, M-BUSState protocol and baud rate when ordering
PowerDC 24 V | AC 85–264 V waterproof adapterState the site supply and whether submersion is required

Installation Notes

  • Mount the host directly on the pipe or on a suitable bracket; after completing wiring, seal the terminal block with the supplied silicone so the mainboard stays watertight.

  • Straight run: 10D upstream, 5D downstream, 30D from a pump outlet or half-open valve.

  • Acceptance: signal strength ≥60 and Q value >60 before trusting the reading.

  • For submerged or flooded locations, confirm enclosure sealing and cable entry with us before installation; cable length and type confirmed per configuration.

Data, Alarms and Batch Control

  • Built-in logger keeps timed and historical records of flow, heat, pressure, level and temperature; power-off records retained.

  • Two alarm channels; relay can drive an external alarm or beacon.

  • Built-in batch controller for preset-volume dosing; 11+ segment linearisation, meter factor, damping and low-flow cut-off.

Typical Applications

  • Underground and wet locations: pits, meter chambers, flooded manholes, utility tunnels, sewage and drainage, groundwater and wells.

  • Water and remote metering: water supply and distribution, irrigation, industrial cooling and circulating water, district heating and cooling, remote or temporary sites, mining and construction water management.

What to Send Us for Selection

Send: whether submersion or flooding is expected, pipe OD and wall thickness, material and lining, fluid and temperature, normal and maximum flow, channel count, transducer style, heat sensors, outputs, communication and supply. We will confirm the transducer model and configuration before quoting.

Frequently Asked Questions

Can the converter operate two metres underwater?

The host is rated IP68 and is designed for submersion to 2 m; the terminal compartment is silicone-sealed after wiring. Confirm the actual water depth and immersion condition with us before ordering.

Is the host fully rated IP68?

Yes. The converter and transducer are sealed for IP68; the supplied silicone fills the terminal block after wiring to keep the mainboard watertight.

Does it support both flow and heat measurement?

Yes. In addition to transit-time flow, three- or four-wire PT100 sensors on the supply and return inputs compute cold and heat energy, with heat units configurable in the menu.

How is the terminal compartment sealed for submerged field installation?

After wiring the terminals, the supplied silicone compound is poured into the terminal compartment to seal the mainboard; cable entries and sealing must follow the installation instructions to retain IP68.

What straight-pipe and signal-quality conditions are required?

Provide 10D upstream and 5D downstream (30D from pumps or half-open valves), and verify signal strength ≥60 and Q >60 before commissioning.

Datasheet Download

HNF100-G Integrated IP68 Ultrasonic Flow Meter Datasheet (PDF) — view all product manuals on our Download page »

Need Us to Check the Wet-Site Application?

Send the immersion condition, pipe size, material, fluid, temperature, channel count and required outputs. We will confirm the transducer model and configuration before quotation.

Send us your application details »