All-in-one on-pipe ultrasonic flow and heat meter with IP68 host, submersible to 2 m; terminal compartment silicone-sealed after wiring. Clamp-on, insertion or pipe-section transducers in single/dual/four channel; PT100 supply/return heat metering; analog, OCT, relay, frequency and RS485 connect directly to the control system, with no wall unit or long cable run.
The HNF100-G is an all-in-one ultrasonic flow and heat meter: the converter mounts directly on the pipe, on a wall or even underwater. The host is rated IP68 and can operate submerged to 2 m; after wiring, the terminal block is filled with the supplied silicone to make the mainboard watertight. No separate instrument panel or cable run to a wall unit is required.
The electronics are sealed together with the pipe assembly, which suits underground pits, meter chambers, flooded manholes, utility tunnels and remote sites where a conventional wall-mounted converter would be exposed. The local display runs the 100+ menu system for pipe size, material, lining, fluid, transducer type and mounting, units, damping, low-flow cut-off, zero calibration, meter factor and 11+ segment linearisation.
Good fit: underground pits and meter chambers, flooded manholes and utility tunnels, water supply and distribution networks, irrigation and agriculture, groundwater and well monitoring, district heating and cooling, HVAC and building services, industrial water and cooling circuits, temporary or remote metering sites, mining and construction water management, sewage and drainage, retrofit where no panel space exists.
Upstream and downstream transducers exchange ultrasound alternately; the transit-time difference between the two directions is proportional to flow velocity. Single, dual or four channels average the velocity profile on large or disturbed mains. Pipe data and fluid properties are entered in the menu; the converter computes transducer spacing and V/Z method.
| Model | HNF100-G — integrated (all-in-one) ultrasonic flow meter / heat meter |
|---|---|
| Protection | Host IP68, submersible to 2 m; terminal compartment silicone-sealed after wiring; transducer IP68 |
| Principle | Ultrasonic transit-time; single, dual or four channel |
| Accuracy | One-channel ±1 %; two- / four-channel ±0.5 %; flow velocity ≥0.3 m/s one-/two-channel, ≥0.1 m/s four-channel |
| Pipe size | DN15–DN6000 |
| Transducer style | Clamp-on, insertion or pipe-section; standard or high-temperature body |
| Fluid | Water, seawater, industrial sewage, various oils and other single-uniform sound-conducting liquids |
| Medium temperature | −30…90 ℃ standard; −30…160 ℃ high-temperature |
| Current output | 4–20 / 0–20 / 0–4–20 mA, accuracy better than 0.1 % |
| OCT pulse | Isolated open-collector, DC 60 V / 100 mA; pulse width 6–1000 ms |
| Relay / frequency | Relay AC 125 V / DC 28 V, 1 A; frequency and cumulative pulse output; two alarms |
| Analog input | 4–20 mA current input, usable as a data collector for temperature, pressure or level |
| Temperature input | Three-wire or four-wire PT100 on supply and return for heat metering |
| Communication | Isolated RS485, MODBUS ASCII/RTU, M-BUS |
| Data and control | Built-in data logger with timed output and history query; batch controller; 11+ segment linearisation, meter factor, damping, low-flow cut-off, zero calibration |
| Power supply | DC 24 V; optional AC 85–264 V waterproof power adapter |
| Ambient / cable | Converter −20…60 ℃; cable length and type confirmed per configuration |
| Style | Use | Pipe size |
|---|---|---|
| Clamp-on | Existing pipe, no shutdown; standard or high-temperature body | DN15–DN6000 |
| Insertion | Large bore, lined or buried pipe, or a surface that cannot be clamped | DN50–DN6000 |
| Pipe-section | High accuracy or special fluid conditions; specified on request | Per configuration |
| Item | Options | Notes |
|---|---|---|
| Channels | Single / dual / four channel | Multi-channel for large pipes and disturbed flow |
| Transducer | Clamp-on / insertion / pipe-section; standard or high temperature | Choose by pipe OD, fluid temperature and access |
| Heat metering | Not fitted | PT100 pair, 3- or 4-wire | Supply and return sensors for cold/heat energy |
| Outputs | 4–20 / 0–20 / 0–4–20 mA, OCT, relay, frequency / cumulative pulse | Configured in the menu |
| Communication | Isolated RS485 Modbus ASCII/RTU, M-BUS | State protocol and baud rate when ordering |
| Power | DC 24 V | AC 85–264 V waterproof adapter | State the site supply and whether submersion is required |
Mount the host directly on the pipe or on a suitable bracket; after completing wiring, seal the terminal block with the supplied silicone so the mainboard stays watertight.
Straight run: 10D upstream, 5D downstream, 30D from a pump outlet or half-open valve.
Acceptance: signal strength ≥60 and Q value >60 before trusting the reading.
For submerged or flooded locations, confirm enclosure sealing and cable entry with us before installation; cable length and type confirmed per configuration.
Built-in logger keeps timed and historical records of flow, heat, pressure, level and temperature; power-off records retained.
Two alarm channels; relay can drive an external alarm or beacon.
Built-in batch controller for preset-volume dosing; 11+ segment linearisation, meter factor, damping and low-flow cut-off.
Underground and wet locations: pits, meter chambers, flooded manholes, utility tunnels, sewage and drainage, groundwater and wells.
Water and remote metering: water supply and distribution, irrigation, industrial cooling and circulating water, district heating and cooling, remote or temporary sites, mining and construction water management.
Send: whether submersion or flooding is expected, pipe OD and wall thickness, material and lining, fluid and temperature, normal and maximum flow, channel count, transducer style, heat sensors, outputs, communication and supply. We will confirm the transducer model and configuration before quoting.
Can the converter operate two metres underwater?
The host is rated IP68 and is designed for submersion to 2 m; the terminal compartment is silicone-sealed after wiring. Confirm the actual water depth and immersion condition with us before ordering.
Is the host fully rated IP68?
Yes. The converter and transducer are sealed for IP68; the supplied silicone fills the terminal block after wiring to keep the mainboard watertight.
Does it support both flow and heat measurement?
Yes. In addition to transit-time flow, three- or four-wire PT100 sensors on the supply and return inputs compute cold and heat energy, with heat units configurable in the menu.
How is the terminal compartment sealed for submerged field installation?
After wiring the terminals, the supplied silicone compound is poured into the terminal compartment to seal the mainboard; cable entries and sealing must follow the installation instructions to retain IP68.
What straight-pipe and signal-quality conditions are required?
Provide 10D upstream and 5D downstream (30D from pumps or half-open valves), and verify signal strength ≥60 and Q >60 before commissioning.
Send the immersion condition, pipe size, material, fluid, temperature, channel count and required outputs. We will confirm the transducer model and configuration before quotation.
Send us your application details »