Rail-mounted multifunctional ultrasonic flow and heat meter module for panel builders, OEM equipment and system integrators. Clips onto a 35 mm DIN rail; clamp-on, bracket, insertion or pipe-section transducers in single or multi-channel. PT100 supply/return sensors for heat metering; analog, relay, OCT, frequency and RS485 connect directly to PLC, DCS or SCADA.
The HNF100-D is a rail-mounted multifunctional ultrasonic flow and heat meter converter for panel builders, OEM equipment and system integrators. It clips onto a standard 35 mm DIN rail, runs the same transit-time platform, and supports clamp-on, bracket, insertion and pipe-section transducers in single or multi-channel configuration. PT100 sensors on the supply and return legs give heat metering; analog, relay, OCT, frequency and RS485 signals connect directly to PLC, DCS or SCADA.
The module is built for embedding in control cabinets, metering skids, heat-meter assemblies and telemetry panels, where a separate wall instrument is not wanted. Over 100 menu windows configure pipe size, material, lining, fluid, transducer type and mounting, with zero calibration, damping, low-flow cut-off, scale-factor correction and 11+ segment linearisation.
Good fit: OEM equipment integration, control cabinet and switchgear builders, metering skids and packaged systems, heat-meter assembly, PLC/DCS/SCADA automation, energy management systems, remote monitoring and telemetry, district heating substations, water utilities, retrofit and converter replacement, embedded flow measurement projects.
Upstream and downstream transducers exchange ultrasound alternately; the transit-time difference between the two directions is proportional to flow velocity. Single, dual or four channels average the velocity profile on large or disturbed mains. Pipe data and fluid properties are entered in the menu; the converter computes transducer spacing and V/Z method.
| Model | HNF100-D — rail-mounted multifunctional ultrasonic flow meter / heat meter module |
|---|---|
| Principle | Ultrasonic transit-time; single, dual or four channel |
| Accuracy | One-channel ±1 %; two- / four-channel ±0.5 % (per channel configuration; flow velocity ≥0.3 m/s one-/two-channel, ≥0.1 m/s four-channel) |
| Pipe size | DN15–DN6000 |
| Transducer style | Clamp-on DN15–DN6000; bracket DN15–DN300; insertion DN50–DN6000; pipe-section |
| Fluid | Water, seawater, industrial sewage, various oils and other single-uniform sound-conducting liquids |
| Medium temperature | −30…90 ℃ standard; −30…160 ℃ high-temperature |
| Current output | 4–20 / 0–20 / 0–4–20 mA, accuracy better than 0.1 % |
| OCT pulse | Isolated open-collector, DC 60 V / 100 mA; pulse width 6–1000 ms |
| Relay / frequency | Relay AC 125 V / DC 28 V, 1 A; frequency and cumulative pulse output; two alarms |
| Analog input | 4–20 mA current input, usable as a data collector for temperature, pressure or level |
| Temperature input | Three-wire or four-wire PT100 on supply and return for heat metering |
| Communication | Isolated RS485, MODBUS ASCII/RTU, M-BUS |
| Data and control | Built-in data logger with timed output and history query; batch controller; 11+ segment linearisation, meter factor, damping, low-flow cut-off, zero calibration |
| Power supply | AC 110–220 V or DC 8–36 V |
| Ambient / protection | Converter −20…60 ℃; transducer IP68 after sealing; converter protection and cable length confirmed per configuration |
| Style | Use | Pipe size |
|---|---|---|
| Clamp-on | Existing pipe, no shutdown; standard or high-temperature body | DN15–DN6000 |
| Bracket / holder | Improved mounting efficiency and repeatability on accessible pipes | DN15–DN300 |
| Insertion | Large bore, lined or buried pipe, or a surface that cannot be clamped | DN50–DN6000 |
| Pipe-section | High accuracy or special fluid conditions; specified on request | Per configuration |
| Item | Options | Notes |
|---|---|---|
| Channels | Single / dual / four channel | Multi-channel for large pipes and disturbed flow |
| Transducer | Clamp-on / bracket / insertion / pipe-section; standard or high temperature | Choose by pipe OD, fluid temperature and access |
| Heat metering | Not fitted | PT100 pair, 3- or 4-wire | Supply and return sensors for cold/heat energy |
| Outputs | 4–20 / 0–20 / 0–4–20 mA, OCT, relay, frequency / cumulative pulse | Configured in the menu |
| Communication | Isolated RS485 Modbus ASCII/RTU, M-BUS | State protocol and baud rate when ordering |
| Power | AC 110–220 V | DC 8–36 V | State the site supply |
Mount the module on a standard 35 mm DIN rail inside the cabinet; terminals connect transducers, PT100, analog inputs, relay, analog output, power and RS485.
Straight run: 10D upstream, 5D downstream, 30D from a pump outlet or half-open valve.
Acceptance: signal strength ≥60 and Q value >60 before trusting the reading.
Keep transducer cable clear of power cables; cable length and type confirmed per configuration.
Built-in logger keeps timed and historical records of flow, heat, pressure, level and temperature; power-off records retained.
Two alarm channels; relay can drive an external alarm or beacon.
Built-in batch controller for preset-volume dosing; 11+ segment linearisation, meter factor, damping and low-flow cut-off.
OEM and automation: control cabinets, switchgear, metering skids, packaged plants, PLC/DCS/SCADA integration.
Energy and water: heat-meter assemblies, district heating substations, water utilities, irrigation, energy monitoring and remote telemetry.
Send: pipe OD and wall thickness, material and lining, fluid and temperature, normal and maximum flow, channel count, transducer style, heat sensors, outputs, communication, supply and cable length. We will confirm the transducer model and configuration before quoting.
Can this converter use multiple measurement channels?
Yes. Single, dual and four-channel versions are available; multi-channel averages the velocity profile on large or disturbed mains, with two-/four-channel accuracy ±0.5 %.
Does it clip onto 35 mm DIN rail?
Yes. The module snaps onto a standard 35 mm DIN rail for batch mounting in instrument boxes and distribution cabinets, intended for embedded OEM integration rather than wall display.
Which inputs support heat metering with PT100 sensors?
Three- or four-wire PT100 sensors connect to the supply and return inputs; the module computes cold and heat energy alongside flow, with heat units configurable in the menu.
How do low-flow cutoff and multipoint linearisation improve system performance?
Adjustable low-flow cut-off, damping, meter factor and 11+ segment linearisation stabilise readings at low flow and compensate for non-uniform flow across the pipe profile.
What outputs connect the embedded module to PLC, DCS or SCADA?
4–20/0–20/0–4–20 mA analog output, isolated OCT pulse, relay, frequency/cumulative pulse, analog inputs and isolated RS485 Modbus ASCII/RTU or M-BUS wire directly to the control system.
Send the pipe size, material, fluid, temperature, channel count and required outputs. We will confirm the transducer model and configuration before quotation.
Send us your application details »