All-metal variable-area rotameter for liquids and gases. DN15–DN150, liquid to 150,000 L/h, gas to 3000 m³/h, ±1.0–1.5% FS, 4–20 mA/HART/RS485, IP65.
The HNF50 all-metal tube float flow meter — also called a metal float flowmeter, metal tube rotameter or variable-area flow meter — measures both liquids and gases. As flow increases, the float rises inside a tapered measuring tube; its position is read on the scale and transferred by a magnetic coupling, so the indicator stays fully sealed from the medium and signal transmission remains stable. The sturdy all-metal design uses an independent modular measuring-tube/indicator concept, with 304, 316, 316L, Hastelloy B/C, titanium or PTFE-lined measuring tube and float for corrosive service, and IP65 protection.
Available in pointer, electric remote, corrosion-resistant, high-voltage, jacket and explosion-proof versions, with analog output, local indication, totalization, digital communication, on-site parameter modification and multiple supply options, plus magnetic filters and special specifications. It serves petroleum, chemical, power generation, pharmaceuticals, food and beverage, water treatment, corrosive acid/alkali media, high-temperature processes, sanitary dairy lines, gas purging and dosing lines in complex and harsh environments.
Good fit: petroleum, chemical industry, power generation, pharmaceuticals, food & beverage, water treatment, corrosive acids and alkalis, high-temperature processes to 350 ℃, sanitary food and dairy lines, gas purging and dosing lines, complex and harsh process environments.
Choose HNF50 when:
You need a rugged variable-area meter for liquid or gas, with local indication and optional remote transmission.
The medium is corrosive, high-temperature, high-pressure or sanitary, requiring stainless, Hastelloy, titanium or PTFE-lined wetted parts.
You want 4–20 mA, HART, RS485/RS232, pulse or relay alarm output, with DC, AC or battery supply.
Confirm with us first when: viscosity exceeds the DN-specific limit, the process pressure/temperature is outside the standard rating, a sanitary or jacketed connection is required, or an explosion-proof version is needed.
On the variable-area principle, flow through the tapered tube lifts the float until the annular gap balances the float weight against flow force. The float position is transferred through the magnetic coupling to the sealed indicator, which shows the flow on the scale and drives the output electronics. Full digital processing gives strong anti-interference, reliable measurement and high accuracy; the low-pressure-loss design and vertical or horizontal installation suit different layouts.
| Model | HNF50 — Metal tube float (variable-area) flow meter |
|---|---|
| Measurement medium | Liquid and gas, compatible with the selected contact material |
| Accuracy | ≤±1.5 % FS typical; ≤±1.0 % FS highest (including nonlinearity, hysteresis and repeatability) |
| Nonlinearity (BFSL) | ≤±0.3 % FS |
| Hysteresis / repeatability | ≤±0.1 % FS |
| Thermal drift | Zero and full range ≤±0.1 % FS/10K typical, ≤±0.2 % FS/10K maximum |
| Range ratio | 10:1; 20:1 customized |
| Nominal size | DN15, DN25, DN50, DN80, DN100, DN150; customized; caliber range DN10…DN2600 |
| Pressure rating | DN15/25/50: 4.0 MPa; DN80/100/150: 1.6 MPa |
| Measuring range | Liquid 1.0–150,000 L/h; gas 0.05–3000 m³/h |
| Medium temperature | Standard −30…+120 ℃; high-temperature 120…350 ℃; PTFE lining up to 80 ℃ |
| Supply | 24 VDC (12–36 VDC); 220 VAC; 3.6 V lithium battery |
| Output signal | Two-wire 4–20 mADC, 4–20 mA + HART; three-wire MODBUS RTU; accumulated pulse (24 V, 50 % duty); optional relay alarm, contact 250 VAC 3 A |
| Output load | 500 Ω (when powered by 24 VDC) |
| Ambient temperature | Local type −40…120 ℃; remote type −30…70 ℃; storage −40…85 ℃, humidity ≤85 % |
| Connection | Flange to GB/T 9119-2000; clamp and sanitary connections; sanitary surface roughness <0.8 Ra |
| Protection rating | IP65 |
| Viscosity limit | DN15 η<5 mPa·s; DN25 η<250 mPa·s; DN50–DN150 η<300 mPa·s |
| Tube / float material | R1 304 (0Cr18Ni9); R0 316 (0Cr18Ni12Mo2Ti); RL 316L (00Cr17Ni14Mo2Ti); H Hastelloy B/C; Ti titanium / titanium alloy; Rp PTFE lining |
| Nominal size | Water / oil (L/h) | Air (m³/h) |
|---|---|---|
| DN15 | 2.5–630 | 0.07–16 |
| DN25 | 100–4,000 | 3–110 |
| DN40 | 500–6,000 | 12–160 |
| DN50 | 630–16,000 | 18–400 |
| DN80 | 2,500–40,000 | 60–800 |
| DN100 | 6,300–63,000 | 100–1,000 |
| DN150 | 20,000–100,000 | 600–3,000 |
Each size offers A–H sub-scales; the exact water/oil and air range and pressure loss for a sub-scale are listed in the datasheet range comparison table.
| Code segment | Code | Description |
|---|---|---|
| Type | A | Sanitary type |
| B | Standard type | |
| Flow range | X | Note the maximum flow rate corresponding to 20 mA after X |
| Nominal size | 10 | DN10 |
| 25 | DN25 | |
| 50 | DN50 | |
| 100 | DN100 | |
| 200 | DN200 | |
| X | Write the diameter directly after X, max 2200 mm | |
| Accuracy | A | 1 % FS |
| B | 1.5 % FS | |
| Signal output | M | 4–20 mA |
| MH | 4–20 mA with HART | |
| P | Pulse output | |
| R2 | RS232 output | |
| R4 | RS485 output | |
| Rod structure | A | Down in, up out |
| B | Right in, left out | |
| C | Left in, right out | |
| Float material | L | 316L |
| O | PTFE | |
| T | Titanium | |
| Shell material | 1 | Carbon steel |
| 2 | Stainless steel | |
| Measurement medium | A | Water |
| B | Air | |
| C | Oil | |
| Pressure / temperature | A | Standard |
| B | High temperature and high pressure | |
| Supply voltage | 1 | DC 24 V |
| 2 | AC 220 V | |
| 3 | 3.6 V lithium battery | |
| Explosion-proof | 1 | Non-explosion-proof |
| 2 | Explosion-proof type |
Vertical and horizontal mounting are supported; match the rod structure code (down-in/up-out, right-in/left-out, left-in/right-out) to the piping orientation.
For liquid service install to avoid gas entrainment; for gas service avoid liquid slugging; a magnetic filter can be fitted where required.
Match tube, float and seal materials to the medium; choose PTFE lining or Hastelloy/titanium for corrosive service.
Confirm viscosity against the DN-specific limit before ordering.
Process industry: petroleum, chemical, power generation, water treatment.
Sanitary and food: pharmaceuticals, food and beverage, dairy lines with <0.8 Ra finish.
Corrosive and high-temperature: acids and alkalis, processes up to 350 ℃, jacketed service.
Gas and dosing: gas purging and dosing lines, compressed-air and fuel-gas measurement.
Send: medium (water/air/oil or other), flow range and normal operating flow, nominal size and connection, required output, supply, wetted/float material, pressure and temperature, sanitary or jacketed requirement, and whether explosion-proof is needed. We will confirm the size and selection code before quoting.
Can one rotameter measure liquids and gases?
Yes. The HNF50 variable-area meter measures both liquids and gases; the medium and sub-scale are selected in the code, with liquid to 150,000 L/h and gas to 3000 m³/h.
Which wetted materials resist corrosive process fluids?
The measuring tube and float can be 304, 316, 316L, Hastelloy B/C, titanium or PTFE-lined. Send the chemical and concentration so we can match the material; PTFE lining is limited to 80 ℃.
Does it support horizontal installation?
Yes. Vertical and horizontal installation are supported; choose the rod structure code that matches inlet/outlet orientation (down-in/up-out, right-in/left-out, left-in/right-out).
How does magnetic coupling isolate the sealed indicator from the measured medium?
The float position is transferred to the indicator through a magnetic coupling, so the indicator is fully sealed from the medium; this keeps signal transmission stable and protects the electronics from aggressive process fluids.
What output and battery options are available for remote flow monitoring?
Outputs include two-wire 4–20 mA and 4–20 mA+HART, three-wire MODBUS RTU, accumulated pulse and optional relay alarm; RS232/RS485 are also selectable. Supply can be DC 24 V, AC 220 V or a 3.6 V lithium battery for locations without mains power.
HNF50 Metal Tube Rotameter Datasheet (PDF) — view all product manuals on our Download page »
Send us the medium, flow range, size and connection. We will confirm the selection code before we quote.
Send us your application details »
Contact: HongNuo
Phone: 13840589744
Tel: 86-13840589744
Email: Guiyang.bai@honno-auto. com
Add: Zhongguancun Innovation Center, No. 28 Huahai Road, Shenyang Economic and Technological Development Zone, Liaoning Province
We chat