Ultrasonic flow and heat meter in a flameproof enclosure for hazardous areas, fixed with four Φ8 expansion bolts. Single/dual/four channel; clamp-on, bracket, insertion or pipe-section transducers; PT100 supply/return heat metering; local LCD/keyboard setup; analog, OCT, relay, frequency and RS485 connect to hazardous-area control systems.
The HNF100-F is an explosion-proof ultrasonic flow and heat meter built for hazardous areas. The converter sits in a flameproof enclosure fixed with four Φ8 expansion bolts, and shares the same wiring scheme as the wall-mounted version: upstream/downstream transducer channels, PT100 inputs, analog inputs, current-loop output, OCT, relay and RS485. Setup and calibration run on the local LCD and keyboard, so no external tools are needed in the unsafe area.
The die-cast aluminum flameproof housing protects the electronics in chemical, petrochemical, oil & gas, solvent and coating plants. The local menu covers pipe parameters, materials, lining, fluid, transducer type and mounting, damping, low-flow cut-off, zero calibration, meter factor and 11+ segment linearisation. Heat metering is added by connecting PT100 sensors to the supply and return pipes.
Good fit: chemical and petrochemical plants, oil & gas and refined products, solvent and coating production, flammable gas and vapor pipelines, refinery utility water, fertilizer plants, paint and ink factories, tank farm and loading areas, hazardous-area water treatment, offshore and marine hazardous zones, explosive-atmosphere process plants.
Upstream and downstream transducers exchange ultrasound alternately; the transit-time difference between the two directions is proportional to flow velocity. Single, dual or four channels average the velocity profile on large or disturbed mains. Pipe data and fluid properties are entered in the menu; the converter computes transducer spacing and V/Z method.
| Model | HNF100-F — explosion-proof ultrasonic flow meter / heat meter |
|---|---|
| Explosion protection | Flameproof Ex d enclosure, rated Ex d IIB T4 per configuration; confirm the certified marking on the nameplate for the intended zone |
| Principle | Ultrasonic transit-time; single, dual or four channel |
| Accuracy | One-channel ±1 %; two- / four-channel ±0.5 %; flow velocity ≥0.3 m/s one-/two-channel, ≥0.1 m/s four-channel |
| Pipe size | DN15–DN6000 |
| Transducer style | Clamp-on DN15–DN6000; bracket; insertion DN50–DN6000; pipe-section |
| Fluid | Water, seawater, industrial sewage, various oils and other single-uniform sound-conducting liquids |
| Medium temperature | −30…90 ℃ standard; −30…160 ℃ high-temperature |
| Housing / protection | Die-cast aluminum flameproof enclosure, IP65; humidity ≤85 %RH; transducer IP68 after sealing |
| Current output | 4–20 / 0–20 / 0–4–20 mA, accuracy better than 0.1 % |
| OCT pulse | Isolated open-collector, DC 60 V / 100 mA; pulse width 6–1000 ms |
| Relay / frequency | Relay AC 125 V / DC 28 V, 1 A; frequency and cumulative pulse output; two alarms |
| Analog input | 4–20 mA current input, usable as a data collector for temperature, pressure or level |
| Temperature input | Three-wire or four-wire PT100 on supply and return for heat metering |
| Communication | Isolated RS485, MODBUS ASCII/RTU, M-BUS |
| Data and control | Built-in data logger with timed output and history query; batch controller; 11+ segment linearisation, meter factor, damping, low-flow cut-off, zero calibration |
| Power supply | AC 110–220 V or DC 8–36 V |
| Ambient / cable | Converter −20…60 ℃; transducer cable up to 200 m; cable length and type confirmed per configuration |
| Style | Use | Pipe size |
|---|---|---|
| Clamp-on | Existing pipe, no shutdown; standard or high-temperature body | DN15–DN6000 |
| Bracket / holder | Improved mounting efficiency and repeatability on accessible pipes | DN15–DN300 |
| Insertion | Large bore, lined or buried pipe, or a surface that cannot be clamped | DN50–DN6000 |
| Pipe-section | High accuracy or special fluid conditions; specified on request | Per configuration |
| Item | Options | Notes |
|---|---|---|
| Channels | Single / dual / four channel | Multi-channel for large pipes and disturbed flow |
| Transducer | Clamp-on / bracket / insertion / pipe-section; standard or high temperature | Choose by pipe OD, fluid temperature and access |
| Explosion rating | Per issued certificate and zone classification | State hazardous-area zone and gas group when ordering |
| Heat metering | Not fitted | PT100 pair, 3- or 4-wire | Supply and return sensors for cold/heat energy |
| Outputs | 4–20 / 0–20 / 0–4–20 mA, OCT, relay, frequency / cumulative pulse | Configured in the menu |
| Communication | Isolated RS485 Modbus ASCII/RTU, M-BUS | State protocol and baud rate when ordering |
| Power | AC 110–220 V | DC 8–36 V | State the site supply |
Fix the flameproof enclosure with four Φ8 expansion bolts on a stable wall or bracket; maintain the wiring scheme for transducer, PT100, analog input, relay, analog output, power and RS485.
Straight run: 10D upstream, 5D downstream, 30D from a pump outlet or half-open valve.
Acceptance: signal strength ≥60 and Q value >60 before trusting the reading; transducer cable up to 200 m.
Keep transducer cable clear of power cables; do not open the enclosure when energized.
Built-in logger keeps timed and historical records of flow, heat, pressure, level and temperature; power-off records retained.
Two alarm channels; relay can drive an external alarm or beacon.
Built-in batch controller for preset-volume dosing; 11+ segment linearisation, meter factor, damping and low-flow cut-off.
Process and hazardous plants: chemical and petrochemical units, oil & gas and refined-product lines, solvent and coating plants, refinery and fertilizer utility water, tank farm loading.
Water and energy in hazardous zones: hazardous-area water treatment, plant cooling and circulating water, district heating substations with flammable atmosphere, remote hazardous-area metering.
Send: hazardous-area zone and gas group, pipe OD and wall thickness, material and lining, fluid and temperature, normal and maximum flow, channel count, transducer style, heat sensors, outputs, communication, supply and cable length. We will confirm the transducer model, configuration and applicable certificate before quoting.
Is the enclosure rated Ex d IIB T4?
It is a flameproof Ex d enclosure built to IIB T4 class per configuration; the exact certified group and temperature class on the nameplate should be matched to the hazardous-area zone before installation. Provide the zone and gas group at enquiry for the correct certificate.
Can it use clamp-on or insertion transducers?
Yes. Clamp-on, bracket, insertion and pipe-section transducers are supported, in standard or high-temperature versions; clamp-on covers DN15–DN6000 and insertion DN50–DN6000.
Does hazardous-area setup use the local keyboard?
Yes. Pipe data, calibration, units, damping, cut-off and linearisation are set on the local LCD and four-key menu, avoiding external tools in the unsafe area.
How much straight pipe is needed upstream and downstream?
Provide 10D upstream and 5D downstream, rising to 30D from a pump outlet or half-open valve; verify signal strength ≥60 and Q >60 before commissioning.
What isolated outputs are available for hazardous-area control and heat metering?
4–20/0–20/0–4–20 mA analog output, isolated OCT pulse, relay, frequency/cumulative pulse, analog inputs and isolated RS485 Modbus ASCII/RTU or M-BUS; PT100 supply/return inputs compute heat energy.
Send the zone classification, gas group, pipe size, fluid, temperature and required outputs. We will confirm the configuration and applicable certificate before quotation.
Send us your application details »