HNF100-E Panel-Mount Ultrasonic Flow Meter for Switchgear

Panel-mount (embedded) ultrasonic flow and heat meter for flush installation into control panels, switchgear doors or instrument boards. ABS housing, local LCD and four-key menu; clamp-on, bracket, insertion or pipe-section transducers in single or dual channel; PT100 supply/return sensors for heat metering; analog, OCT, relay, frequency and RS485 connect to PLC, DCS or SCADA.

HNF100-E Panel-Mount Ultrasonic Flow Meter

The HNF100-E is a panel-mount (embedded) ultrasonic flow and heat meter built for flush installation into a control panel, switchgear door or instrument board. It uses the same transit-time platform and LCD/keyboard operation as the wall-mounted version, so flow, heat and alarm values are displayed exactly where operators work, with no separate wall instrument. It supports clamp-on, bracket, insertion and pipe-section transducers in single or dual channel, and heat metering with PT100 supply/return sensors.

INQUIRY

Built into the Panel Instrumentation

The ABS engineering-plastic housing sits flush in a panel cut-out; the local LCD and four-key menu configure pipe size, material, lining, fluid, transducer type and mounting, units, damping, cut-off, zero calibration, meter factor and 11+ segment linearisation. The meter becomes part of the panel rather than a stand-alone device.

Good fit: control panel and switchgear integration, boiler room and heat-exchange station instrumentation, pump stations, packaged and containerized plants, machine control boards, water treatment control rooms, HVAC plant rooms, district heating substations, energy management displays, factory utility monitoring, retrofit of existing panels.

Working Principle

Upstream and downstream transducers exchange ultrasound alternately; the transit-time difference between the two directions is proportional to flow velocity. Single or dual channel averages the velocity profile on large or disturbed mains. Pipe data and fluid properties are entered in the menu; the converter computes transducer spacing and V/Z method.

Technical Specifications

ModelHNF100-E — panel-mount ultrasonic flow meter / heat meter
PrincipleUltrasonic transit-time; single or dual channel
AccuracyOne-channel ±1 %; two-channel ±0.5 %; flow velocity ≥0.3 m/s
Pipe sizeDN15–DN6000
Transducer styleClamp-on DN15–DN6000; bracket DN15–DN300; insertion DN50–DN6000; pipe-section
FluidWater, seawater, industrial sewage, various oils and other single-uniform sound-conducting liquids
Medium temperature−30…90 ℃ standard; −30…160 ℃ high-temperature
HousingABS engineering plastic, flush panel mounting; converter IP68, humidity ≤80 %RH
Current output4–20 / 0–20 / 0–4–20 mA, accuracy better than 0.1 %
OCT pulseIsolated open-collector, DC 60 V / 100 mA; pulse width 6–1000 ms
Relay / frequencyRelay AC 125 V / DC 28 V, 1 A; frequency and cumulative pulse output; two alarms with buzzer
Analog input4–20 mA current input, usable as a data collector for temperature, pressure or level
Temperature inputThree-wire or four-wire PT100 on supply and return for heat metering
CommunicationIsolated RS485, MODBUS ASCII/RTU, M-BUS
Data and controlBuilt-in data logger with timed output and history query; batch controller; 11+ segment linearisation, meter factor, damping, low-flow cut-off, zero calibration
Power supplyAC 110–220 V or DC 8–36 V
AmbientConverter −20…60 ℃; transducer IP68 after sealing; cable length confirmed per configuration

Transducer Options

StyleUsePipe size
Clamp-onExisting pipe, no shutdown; standard or high-temperature bodyDN15–DN6000
Bracket / holderImproved mounting efficiency and repeatability on accessible pipesDN15–DN300
InsertionLarge bore, lined or buried pipe, or a surface that cannot be clampedDN50–DN6000
Pipe-sectionHigh accuracy or special fluid conditions; specified on requestPer configuration

How to Specify

ItemOptionsNotes
ChannelsSingle / dual channelDual channel for large pipes and disturbed flow
TransducerClamp-on / bracket / insertion / pipe-section; standard or high temperatureChoose by pipe OD, fluid temperature and access
Heat meteringNot fitted | PT100 pair, 3- or 4-wireSupply and return sensors for cold/heat energy
Outputs4–20 / 0–20 / 0–4–20 mA, OCT, relay, frequency / cumulative pulseConfigured in the menu
CommunicationIsolated RS485 Modbus ASCII/RTU, M-BUSState protocol and baud rate when ordering
PowerAC 110–220 V | DC 8–36 VState the site supply

Installation Notes

  • Cut a standard panel opening and fix the housing from the rear; terminals connect transducers, PT100, analog inputs, relay, analog output, power and RS485.

  • Straight run: 10D upstream, 5D downstream, 30D from a pump outlet or half-open valve.

  • Acceptance: signal strength ≥60 and Q value >60 before trusting the reading.

  • Keep transducer cable clear of power cables; cable length and type confirmed per configuration.

Data, Alarms and Batch Control

  • Built-in logger keeps timed and historical records of flow, heat, pressure, level and temperature; power-off records retained.

  • Two alarm channels with buzzer; relay can drive an external alarm or beacon.

  • Built-in batch controller for preset-volume dosing; 11+ segment linearisation, meter factor, damping and low-flow cut-off.

Typical Applications

  • Panel and packaged plants: switchgear doors, machine control boards, packaged equipment, boiler rooms, pump stations, water treatment and HVAC control rooms.

  • Energy and water: heat-exchange stations, district heating, water utilities, irrigation, energy monitoring and retrofit of existing panels.

What to Send Us for Selection

Send: panel cut-out, pipe OD and wall thickness, material and lining, fluid and temperature, normal and maximum flow, channel count, transducer style, heat sensors, outputs, communication and supply. We will confirm the transducer model and configuration before quoting.

Frequently Asked Questions

Does it mount flush in a control panel?

Yes. The ABS housing fits a standard panel cut-out and is fixed from the rear, so the display and keypad sit level with the switchgear door or instrument board.

Can it calculate heat from PT100 inputs?

Yes. Three- or four-wire PT100 sensors connect to the supply and return inputs; the meter computes cold and heat energy alongside flow, with heat units configurable in the menu.

Which pipe sizes and transducers are supported?

Clamp-on DN15–DN6000, bracket DN15–DN300, insertion DN50–DN6000 and pipe-section transducers are available, in standard or high-temperature versions by fluid temperature.

Are flow, heat and alarm values displayed where panel operators work?

Yes. The local LCD sits in the panel face and shows flow, heat, totals and alarms at the operator station, removing the need for a separate wall converter.

What interfaces integrate the panel meter with switchgear and packaged plants?

4–20/0–20/0–4–20 mA analog output, isolated OCT pulse, relay, frequency/cumulative pulse, analog inputs and isolated RS485 Modbus ASCII/RTU or M-BUS connect directly to the plant control system.

Datasheet Download

HNF100-E Panel-Mount Ultrasonic Flow Meter Datasheet (PDF) — view all product manuals on our Download page »

Need Us to Check the Application?

Send the panel opening, pipe size, material, fluid, temperature, channel count and required outputs. We will confirm the transducer model and configuration before quotation.

Send us your application details »